Parameters and firmware blocks
89
Parameters and firmware blocks
What this chapter contains
This chapter lists and describes the parameters provided by the firmware.
Types of parameters
Parameters are user-adjustable operation instructions of the drive (groups 10…99).
There are four basic types of parameters: Actual signals, value parameters, value
pointer parameters and bit pointer parameters.
Actual signal
Type of parameter that is the result of a measurement or calculation by the drive.
Actual signals can be monitored, but not adjusted, by the user. Actual signals are
typically contained within parameter groups 1…9.
For additional actual signal data, eg, update cycles and fieldbus equivalents, see
chapter
.
Value parameter
A value parameter has a fixed set of choices or a setting range.
Example 1: Motor phase loss supervision is activated by selecting
from the
selection list of parameter
Example 2: The motor nominal power (kW) is set by writing the appropriate value to
parameter
, eg, 10.
Value pointer parameter
A value pointer parameter points to the value of another parameter. The source
parameter is given in format
P.xx.yy
, where xx = Parameter group; yy = Parameter
index. In addition, value pointer parameters may have a set of pre-selected choices.
Example: Motor current signal,
, is connected to analogue
output AO1 by setting parameter
to value P.01.05.
Bit pointer parameter
A bit pointer parameter points to the value of a bit in another parameter, or can be
fixed to 0 (FALSE) or 1 (TRUE). In addition, bit pointer parameters may have a set of
pre-selected choices.
When adjusting a bit pointer parameter on the optional control panel, CONST is
selected in order to fix the value to 0 (displayed as “C.FALSE”) or 1 (“C.TRUE”).
POINTER is selected to define a source from another parameter.
A pointer value is given in format
P.xx.yy.zz
, where xx = Parameter group,
yy = Parameter index, zz = Bit number.
Example: Digital input DI5 status,
bit 4, is used for brake
supervision by setting parameter
to value P.02.01.04.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...