Standard function blocks
343
SR-D
(10039)
Illustration
Execution time
1.04 µs
Operation
When clock input (C) is set to 1, the data input (D) value is stored to the output (O).
When reset input (R) is set to 1, the output is set to 0.
If only set (S) and reset (R) inputs are used, SR-D block acts as an
block:
The output is 1 if the set input (S) is 1. The output will retain the previous output state if
the set input (S) and reset input (R) are 0. The output is 0 if the set input is 0 and the
reset input is 1.
Truth table:
Inputs
Set input (S): Boolean
Data input (D): Boolean
Clock input (C): Boolean
Reset input (R): Boolean
Outputs
Output (O): Boolean
SR-D
69
TLA1 1 msec
(1)
S
D
>C
R
O
O(69)
S
R
D
C
O
previous
O
0
0
0
0
0
0 (= Previous output value)
0
0
0
0 -> 1
0
0 (= Data input value)
0
0
1
0
0
0 (= Previous output value)
0
0
1
0 -> 1
0
1 (= Data input value)
0
1
0
0
1
0 (Reset)
0
1
0
0 -> 1
0
0 (Reset)
0
1
1
0
0
0 (Reset)
0
1
1
0 -> 1
0
0 (Reset)
1
0
0
0
0
1 (= Set value)
1
0
0
0 -> 1
1
0 (= Data input value) for
one execution cycle, then
changes to 1 according to
the set input (S = 1).
1
0
1
0
1
1 (= Set value)
1
0
1
0 -> 1
1
1 (= Data input value)
1
1
0
0
1
0 (Reset)
1
1
0
0 -> 1
0
0 (Reset)
1
1
1
0
0
0 (Reset)
1
1
1
0 -> 1
0
0 (Reset)
O
previous
is the previous cycle output value.
Summary of Contents for ACSM1 Series
Page 1: ...ABB motion control drives Firmware manual ACSM1 motion control program ...
Page 4: ......
Page 34: ...Drive programming using PC tools 34 ...
Page 86: ...Drive control and features 86 ...
Page 265: ...Parameters and firmware blocks 265 1 100 us 100 µs 2 1 ms 1 ms 3 50 ms 50 ms ...
Page 302: ...Parameter data 302 ...
Page 422: ...Application program template 422 ...
Page 430: ...Appendix A Fieldbus control 430 ...
Page 500: ...Appendix D Application examples 500 ...
Page 508: ...Appendix E Control chain and drive logic diagrams 508 ...
Page 510: ...3AFE68848270 REV H EN 2015 06 26 Contact us www abb com drives www abb com drivespartners ...