Signals and parameters 31
Parameters listing
Actual signals
No.
Name/Value
Description
09
09 Centrifuge
Centrifuge and Decanter actual signals.
All parameters in this group are read-only unless
otherwise specified.
09.01 Centrifuge
status word
Status bit signals of Centrifuge.
-
0000h...FFFFh
Centrifuge status word.
1 = 1
9.02
Centrifuge
stage
Shows actual stage of Centrifuge sequence. See
section
.
-
Stopped
Drive is not running.
0
Accelerating to
fill speed
Drive is accelerating to the filling speed. See parameter
.
1
Pre wash
Drive is at pre-wash speed. See parameter
.
2
Filling
Drive is at filling speed. See parameter
3
Accelerating to
spin speed
Drive is accelerating to spinning speed. See parameter
4
Washing
Drive is at washing speed. See parameter
5
Spinning
Drive is at spinning speed. See parameter
.
6
Decelerating to
unload speed
Drive is decelerating to unload speed. See parameter
.
7
Unloading
Drive is at unload speed. See parameter
.
8
Decelerating to
stop
Decelerating to stop after discharge. See parameter
.
9
Bit
Name
Description
0
Accelerating to fill
speed
1 = Accelerating to filling speed. See parameter
.
1
Pre wash
1 = Sequence is at pre-washing stage.
2
Filling
1 = Sequence is at filling stage.
3
Accelerating to spin
speed
1 = Accelerating to spinning speed. See parameter
4
Washing
1 = Sequence is at washing stage that is speed is more
than the value in parameter
5
Spinning
1 = Sequence is at spinning stage.
6
Decelerating to unload
speed
1 = Decelerating to unloading speed. See parameter
7
Unloading
1 = Sequence is at unloading speed.
8
Decelerating to stop
1 = Deceleration to stop after unloading.
9
Manual halt active
1 = Manual halt is active.
10...15
Reserved