Check that …
The supply voltage matches the nominal input voltage of the drive. Check the type designation label.
The input power cable has been connected to the appropriate terminals, the phase order is right, and
the terminals have been tightened. (Pull on the conductors to check.)
Appropriate AC fuses and a main disconnector have been installed.
The motor cable has been connected to the appropriate terminals, the phase order is right, and the
terminals have been tightened. (Pull on the conductors to check.)
The brake resistor (if present) has been connected to the appropriate terminals, and the terminals have
been tightened. (Pull on the conductors to check.)
The motor cable (and brake resistor cable, if present) has been routed away from other cables.
No power factor compensation capacitors have been connected to the motor cable.
The control cables (if any) have been connected to the appropriate terminals, and the terminals have
been tightened. (Pull on the conductors to check.)
If a drive bypass connection will be used: The direct-on-line contactor of the motor and the drive output
contactor are either mechanically or electrically interlocked, ie, cannot be closed simultaneously.
There are no tools, foreign objects or dust from drilling inside the drive.
All shrouds and cover of the motor connection box are in place. Cabinet doors have been closed.
The motor and the driven equipment are ready for start.
Installation checklist 53
Summary of Contents for ACS880 P940 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 P940 and P944 drive modules Supplement ...
Page 2: ......
Page 4: ......
Page 8: ...8 ...
Page 14: ...14 ...
Page 20: ...20 ...
Page 32: ...32 ...
Page 54: ...54 ...
Page 58: ...R1 Option P940 IP20 UL Type Open 3AUA0000097621 58 Dimension drawings ACS880 01 ...
Page 59: ...R1 Option P944 IP20 UL Type Open 3AUA0000097621 Dimension drawings ACS880 01 59 ...
Page 60: ...R2 Option P940 IP20 UL Type Open 3AUA0000097691 60 Dimension drawings ACS880 01 ...
Page 61: ...R2 Option P944 IP20 UL Type Open 3AUA0000097691 Dimension drawings ACS880 01 61 ...
Page 62: ...R3 Option P940 IP20 UL Type Open 3AUA0000097847 62 Dimension drawings ACS880 01 ...
Page 63: ...R3 Option P944 IP20 UL Type Open 3AUA0000097847 Dimension drawings ACS880 01 63 ...
Page 65: ...R4 Option P944 IP20 UL Type Open 3AUA0000098285 Dimension drawings ACS880 01 65 ...
Page 67: ...R5 Option P944 IP20 UL Type Open 3AUA0000097965 Dimension drawings ACS880 01 67 ...
Page 68: ...R6 Option P940 IP20 UL Type Open 3AUA0000098321 68 Dimension drawings ACS880 01 ...
Page 69: ...R6 Option P944 IP20 UL Type Open 3AUA0000098321 Dimension drawings ACS880 01 69 ...
Page 70: ...R7 Option P940 IP20 UL Type Open 3AUA0000073149 70 Dimension drawings ACS880 01 ...
Page 71: ...R7 Option P944 IP20 UL Type Open 3AUA0000073149 Dimension drawings ACS880 01 71 ...
Page 72: ...R8 Option P940 IP20 UL Type Open 3AUA0000073150 72 Dimension drawings ACS880 01 ...
Page 73: ...R8 Option P944 IP20 UL Type Open 3AUA0000073150 Dimension drawings ACS880 01 73 ...
Page 74: ...R9 Option P940 IP20 UL Type Open 3AUA0000073151 74 Dimension drawings ACS880 01 ...
Page 75: ...R9 Option P944 IP20 UL Type Open 3AUA0000073151 Dimension drawings ACS880 01 75 ...
Page 76: ...76 ...