Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
7
Advanced Standstill ID run.
This selection is recommended with AC induction
motors up to 75 kW instead of the
ID run if
•
the exact nominal ratings of the motor are not
known, or
•
the control performance of the motor is not
satisfactory after a
ID run.
Note: The time it takes for the
ID
run to complete varies according to motor size. With
a small motor, the ID run typically completes within 5
minutes; with a large motor, the ID run may take up to
an hour.
Advanced Standstill
None / uint16
Displays the type of ID run that was performed last.
For more information about the different modes, see
the selections of parameter
Last ID run
performed
99.14
0
No ID run has been performed.
None
1
ID run.
Normal
2
ID run.
Reduced
3
ID run.
Standstill
4
Autophasing
5
Current measurement calibration
.
Current
measurement
calibration
6
ID run.
Advanced
7
ID run.
Advanced Standstill
0 / uint16
Calculated number of pole pairs in the motor.
This parameter is read-only.
Motor polepairs
calculated
99.15
1 = 1 / 1 = 1
Number of pole pairs.
0...1000
542 Parameters