Def / Type
FbEq 16b / 32b
Description
Name / Range /
Selection
No.
14
The start and stop commands are taken from the
embedded fieldbus interface.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
Embedded fieldbus
15
The start and stop commands are taken from another
drive through the master/follower link.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
M/F link
21
The start and stop commands are taken from the
application program control word (parameter
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
Application Program
22
Reserved.
ATF
16
The start and stop commands are taken from an
external (DDCS) controller.
Note: The start signal is always level-triggered with
this setting regardless of parameter
.
DDCS controller
Edge / uint16
Defines whether the start signal for external control
location EXT1 is edge-triggered or level-triggered.
Note: This parameter is only effective when parameter
is set to
,
,
, or
.
Ext1 start trigger
type
20.2
0
The start signal is edge-triggered.
Edge
1
The start signal is level-triggered.
Level
DI1 / uint32
Selects source 1 for parameter
.
Ext1 in1 source
20.3
0
0 (always off).
Not selected
1
1 (always on).
Selected
2
Digital input DI1 (
, bit 0).
DI1
3
Digital input DI2 (
, bit 1).
DI2
4
Digital input DI3 (
, bit 2).
DI3
5
Digital input DI4 (
, bit 3).
DI4
6
Digital input DI5 (
, bit 4).
DI5
7
Digital input DI6 (
, bit 5).
DI6
10
Digital input/output DIO1 (
, bit
0).
DIO1
11
Digital input/output DIO2 (
, bit
1).
DIO2
Parameters 243
Summary of Contents for ACS880 N5700 Series
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 position control program N5700 Firmware manual ...
Page 2: ......
Page 4: ......
Page 22: ...22 ...
Page 28: ...28 ...
Page 32: ...32 ...
Page 60: ...60 ...
Page 546: ...546 ...
Page 604: ...604 ...
Page 626: ...626 ...
Page 640: ...640 ...
Page 660: ...660 ...