116 Parameters
0…150%
Main cooling fan age.
1 = 1%
Displays the age of the auxiliary cooling fan as a
percentage of its estimated lifetime. The estimate is based
on the duty, operating conditions and other operating
parameters of the fan. When the counter reaches 100%, a
warning (
) is generated.
Can be reset from the control panel by keeping Reset
depressed for over 3 seconds.
-
0…150%
Auxiliary cooling fan age.
1 = 1%
0000h...FFFFh
Main control word.
1 = 1
06
Drive control and status words.
The main control word of the drive. This parameter shows
the control signals as received from the selected sources
(such as digital inputs, the fieldbus interfaces and the
application program).
The bit assignments of the word are as described on
page
. The related status word and state diagram are
presented on pages
respectively.
Note:
Bits 12…15 can be used to carry additional control
data, and used as a signal source by any binary-source
selector parameter.
This parameter is read-only.
-
0000h...FFFFh
Main control word.
1 = 1
The drive control word received from the application
program (if any). The bit assignments are described on
page
This parameter is read-only.
-
0000h...FFFFh
Application program control word.
1 = 1
FBA A transparent
control word
The unaltered control word received from the PLC through
fieldbus adapter A.
This parameter is read-only.
-
00000000h
…FFFFFFFFh
Control word received through fieldbus adapter A.
-
FBA B transparent
control word
The unaltered control word received from the PLC through
fieldbus adapter B.
This parameter is read-only.
-
00000000h
…FFFFFFFFh
Control word received through fieldbus adapter B.
1 = 1
The unaltered control word received from the PLC through
the embedded fieldbus interface.
This parameter is read-only.
-
00000000h …
FFFFFFFFh
Control word received through the embedded fieldbus
interface.
1 = 1
No.
Name/Value
Description
Def/
FbEq16
Summary of Contents for ACS880 ESP
Page 1: ...ABB industrial drives Firmware manual ACS880 PCP ESP control program ...
Page 4: ......
Page 28: ...28 PCP ESP control start up ...
Page 30: ...30 Using the control panel ...
Page 94: ...94 Standard programposi features ...
Page 100: ...100 Default control connections ...
Page 360: ...360 Parameters ...
Page 436: ...436 Fault tracing ...
Page 486: ...486 Control chain diagrams ...
Page 492: ...492 Appendix ESP with step up transformer and sine filter ...
Page 494: ...Contact us www abb com drives www abb com drivespartners 3AXD50000016186 Rev B EN 2015 10 27 ...