200 Technical data
sufficient. If in doubt, the supply transformer with static screening between the primary
and secondary windings can be used.
2. An EMC plan for preventing disturbances is drawn up for the installation. A template is
available from the local ABB representative.
3. The motor and control cables are selected as specified in the hardware manual.
4. The drive is installed according to the instructions given in the hardware manual.
WARNING!
A drive of category C4 is not intended to be used on a low-voltage public
network which supplies domestic premises. Radio frequency interference is expected if
the drive is used on such a network.
UL checklist
WARNING!
Operation of this drive requires detailed installation and operation
instructions provided in the hardware and firmware manuals. The manuals can be
found on the Internet. Depending on the product series, the drive package may
contain the manuals in electric format or as hard copies (as standard or ordered with
option codes with the drive). Hard copies of the manuals can also be ordered through the
manufacturer separately. Retain the hard copies of the manuals with the drive.
•
Make sure that the drive type designation label includes the cULus Listed marking.
•
CAUTION - Risk of electric shock
. After disconnecting the input power, always wait
for 5 minutes to let the intermediate circuit capacitors discharge before you start
working on the drive, motor or motor cable.
•
The drive is to be used in a heated, indoor controlled environment. The drive must be
installed in clean air according to enclosure classification. Cooling air must be clean,
free from corrosive materials and electrically conductive dust. See page
•
The maximum ambient air temperature is 40 °C (104 °F) at rated current. The current
is derated for 40 to 55 °C (104 to 131 °F).
•
The drive is suitable for use in a circuit capable of delivering not more than 100,000
rms symmetrical amperes, 600 V maximum, when protected with fuses listed on page
The ampere rating is based on tests done according to UL 61800-5-1.
•
The cables located within the motor circuit must be rated for at least 75 °C (167 °F) in
UL-compliant installations.
Low voltage
Equipment
Low voltage
Equipment
Equipment
(victim)
Supply transformer
Medium voltage network
Static screen
Point of measurement
Drive
Neighboring network
Summary of Contents for ACS880-34
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 34 drive modules 132 to 400 kW 200 to 450 hp Hardware manual ...
Page 4: ......
Page 14: ...14 ...
Page 22: ...22 Safety instructions ...
Page 28: ...28 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 118: ...118 External control unit ...
Page 140: ...140 Installation example with full cabling panels option H381 M8 16 Hex 2 5 4 3 1 1 1 1 2 6 7 ...
Page 152: ...152 Installation checklist ...
Page 156: ...156 Start up ...
Page 158: ...158 Fault tracing ...
Page 174: ...174 Maintenance ...
Page 202: ...202 Technical data EU Declaration of Conformity Machinery Directive ...
Page 204: ...204 Technical data ...
Page 206: ...206 Dimension drawings Standard configuration 3AXD50000038012 ...
Page 208: ...208 Dimension drawings Drive module with options 0B051 H356 0H371 3AXD50000038012 ...
Page 209: ...Dimension drawings 209 Configuration with option H381 3AXD50000323210 ...
Page 210: ...210 Dimension drawings LCL filter module 3AXD50000206162 ...
Page 214: ...214 Dimension drawings External control unit 3axd50000011687 ...
Page 238: ...238 Resistor braking ...
Page 242: ...242 du dt and sine filters ...
Page 256: ...Contact us www abb com drives www abb com drivespartners 3AXD50000035191 Rev B EN 2018 09 28 ...