Control electronics
Cabling of the electronics outside the module must be done by the customer. The current
consumption of the main components in the auxiliary circuit is shown in the technical data.
■
Control unit
You must equip each DC/DC converter unit with one control unit (and memory unit). The
control unit is delivered with a memory unit containing the ACS880 DC/DC converter control
program.
Illustration
Ordering code
Qty
Control unit
Frame
size
Used with…
U
N
= 690 V
3AXD50000022059
1
Control unit
BCU-02 kit for
R8i DDC
R8i
ACS880-1604LC-
0400A-7
R8i
ACS880-1604LC-
0500A-7
R8i
ACS880-1604LC-
0600A-7
R8i
ACS880-1604LC-
0700A-7
R8i
ACS880-1604LC-
0800A-7
R8i
ACS880-1604LC-
0900A-7
3AXD50000022060
1
Control unit
BCU-12 kit *
for R8i DDC
2×R8i
ACS880-1604LC-
1000A-7
2×R8i
ACS880-1604LC-
1200A-7
2×R8i
ACS880-1604LC-
1400A-7
2×R8i
ACS880-1604LC-
1600A-7
2×R8i
ACS880-1604LC-
1800A-7
* Frame sizes 2×R8i can also use BCU-02 if the BAMU voltage/current measurement unit
is not in use.
The BCU control unit kit contains:
•
BCU-02 or BCU-12 control unit
•
memory unit with DC/DC converter control program.
You must connect the control unit to each DC/DC converter module with a pair of fiber optic
cables. You can order them from ABB. See section
.
You can supply 24 V DC for the control unit from the DC/DC converter module. (Alternatively,
you can take the power supply from another suitable power source). You must acquire the
cables separately. Use a suitable standard installation cable. Use appropriate [X53] plug
96 Ordering information
Summary of Contents for ACS880-1604LC
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 1604LC DC DC converter modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 12: ...12 ...
Page 16: ...16 ...
Page 34: ...34 ...
Page 42: ...Kits for ACS880 1604LC R8i unit in Rittal VX25 cabinets 42 Cabinet construction ...
Page 43: ...Stage 1 Installation of common parts Cabinet construction 43 10 ...
Page 45: ...Stage 3 Module installation parts Cabinet construction 45 10 ...
Page 46: ...Stage 4 DDC and energy storage connection 46 Cabinet construction ...
Page 47: ...Stage 5A DC connection with charging Cabinet construction 47 10 ...
Page 48: ...Stage 5B DC connection without charging 48 Cabinet construction ...
Page 49: ...Stage 6 Cooling components Cabinet construction 49 10 ...
Page 50: ...Stage 7 DDC module and filter installation 50 Cabinet construction ...
Page 51: ...Stage 8 Swing frame and shroud installation Cabinet construction 51 10 ...
Page 58: ...58 ...
Page 72: ...72 ...
Page 124: ...124 ...
Page 138: ...138 ...
Page 148: ...148 ...
Page 150: ...R8i DC DC converter module 150 Dimension drawings ...
Page 151: ...BDCL filter module Dimension drawings 151 ...
Page 152: ...Quick connector 152 Dimension drawings ...
Page 153: ...BCU control unit Dimension drawings 153 ...
Page 154: ...BAMU voltage current measurement unit Dimensions in mm 1 mm 0 0394 in 154 Dimension drawings ...