Description
Example value
Name
Index
Sets the maximum ramp time for the SAR1
ramp monitoring.
3000 ms
SAR1 max ramp
time to zero
SARx.22
Time monitoring
: This value has no effect
in the operation.
Ramp monitoring
: Sets the maximum stop
ramp time for the emergency stop. Adjust
the default value when necessary.
I/O settings
Sets the diagnostic pulse of digital input
X113:4 on or off.
On
DI X113:4 diag pulse
on/ off
SAFEIO.36
On
: The input monitors that it receives test
pulses.
Sets the diagnostic pulse of digital input
X114:4 on or off.
On
DI X114:4 diag pulse
on/ off
SAFEIO.40
On
: The input monitors that it receives test
pulses.
Sets the diagnostic pulse of digital output
X114:8 on or off.
On
DO X114:8 diag
pulse on/off
SAFEIO.57
On
: The output monitors that it receives test
pulses.
Sets the logic state of digital output X114:8.
Active high
DO X114:8 logic
state
SAFEIO.75
Active high
: The digital output is on when
the indicated signal is active.
For the Q965, ABB has configured
the SLS indication signal to this digital out-
put at the factory. Make sure that this value
corresponds to the actual wiring. See the
circuit diagrams of the delivery.
Parameters for the SMS function
These parameters are related to the SMS function (version 1) of the FSO module.
Description
Example value
Name
Index
Activates or deactivates the SMS function
and shows the version of the SMS function.
Version 1
SMS activity and
version
200.71
Disabled
: Deactivates the SMS function
(default).
Version 1
: Activates version 1 of the SMS
function.
Version 2
: Activates version 2 of the SMS
function (for more information, see the FSO
module user’s manual).
For the Q965, ABB has configured
the SMS function (Version 1) at the factory.
Adjust the value if necessary.
Note:
The default value after factory reset
is
Disabled
.
Always check this parameter after factory
reset.