Note: To achieve the rated motor power given in the table, the rated current of the drive must be higher
than or equal to the rated motor current. The power ratings apply to most IEC 34 motors at the nominal
voltage of the drive.
ABB recommends to select the drive, motor and gear combination for the required motion profile with
the DriveSize dimensioning tool available from ABB.
■
High speed mode
The selection High speed mode of parameter 95.15 Special HW settings improves
control performance at high output frequencies. ABB recommends it to be selected
with output frequency of 120 Hz and above.
This table gives the drive module ratings for 120 Hz output frequency and the maximum
output frequency when High speed mode in parameter 95.15 Special HW settings is
enabled. With output frequencies lower than the maximum output frequency, the
current derating is less than the value given in the table. Contact ABB for operation
above the recommended maximum output frequency or for the output current derating
with output frequencies above 120 Hz and below the maximum output frequency.
Deratings with selection High speed mode of parameter 95.15 Special HW settings
ACS880-
04F-…
Maximum output frequency
120 Hz output frequency
Heavy-
duty
use
Light-
duty
use
Nominal use
Maxim-
um fre-
quency
Heavy-
duty
use
Light-
duty
use
Nominal use
Fre-
quency
I
Hd
I
Ld
P
n
I
2
f
max
I
Hd
I
Ld
P
n
I
2
f
A
A
kW
A
Hz
A
A
kW
A
Hz
U
n
= 400 V
290
370
200
390
500
361
485
250
504
120
504A-3
311
419
250
437
500
429
575
315
584
120
584A-3
346
466
250
485
500
477
634
355
649
120
649A-3
390
496
250
519
500
566
715
400
725
120
725A-3
431
562
315
587
500
625
810
450
820
120
820A-3
500*
600
355
630
500
725*
865
500
880
120
880A-3
U
n
= 500 V
265
345
250
357
500
330
450
315
459
120
459A-5
290
370
250
390
500
361
483
355
502
120
502A-5
298
380
250
400
500
414
573
400
582
120
582A-5
298
392
250
410
500
477
623
450
634
120
634A-5
362
428
315
462
500
566
705
500
715
120
715A-5
400
490
355
530
500
625
807
560
820
120
820A-5
410
510
400
550
500
697**
857
630
880
120
880A-5
U
n
= 690 V
157
222
200
232
375
255
320
315
329
120
329A-7
200
250
250
260
375
325
360
355
369
120
369A-7
236***
280
250
290
375
360***
420
400
429
120
429A-7
238
261
250
270
375
415
455
450
470
120
470A-7
262
290
250
300
375
455
505
500
522
120
522A-7
300
330
315
340
375
505
571
560
590
120
590A-7
Technical data 137
Summary of Contents for ACS880-04F-504A-3
Page 1: ... ABB INDUSTRIAL DRIVES ACS880 04F drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 36: ...36 ...
Page 44: ...44 ...
Page 50: ...50 Mechanical installation ...
Page 56: ...56 ...
Page 116: ...116 ...
Page 122: ...4 3 2 122 Maintenance ...
Page 128: ...128 ...
Page 143: ... Package dimensions Package dimensions without IP shroud kit Technical data 143 ...
Page 158: ...158 ...
Page 160: ...Standard configuration IP20 UL Type Open 160 Dimension drawings ...
Page 161: ...Drive module with options E208 and H370 IP20 UL Type Open Dimension drawings 161 ...
Page 162: ...Drive module with options 0B051 E208 0H371 IP00 UL Type Open 162 Dimension drawings ...
Page 163: ...Drive module with options 0B051 E208 0H371 C217 IP00 UL Type Open Dimension drawings 163 ...
Page 164: ...Drive module with options 0B051 0H371 IP00 UL Type Open 164 Dimension drawings ...
Page 165: ...Mounting plate opening 3AXD50000038119 Dimension drawings 165 ...
Page 166: ...3AXD50000038119 166 Dimension drawings ...
Page 167: ...External control unit 3AXD50000011687 Dimension drawings 167 ...
Page 168: ...168 ...