484 Parameters
Fieldbus A
Fieldbus interface A.
3
Fieldbus B
Fieldbus interface B.
4
D2D or M/F
The master station on a master/follower or drive-to-drive link. 5
Embedded FB
Embedded fieldbus interface.
6
Embedded Ethernet Ethernet port on type BCU control unit.
7
Panel link
Control panel, or Drive composer PC tool connected to the
control panel.
8
Ethernet tool link
Drive composer PC tool through an FENA module.
9
M/F and D2D clock
synchronization
In the master drive, activates clock synchronization for
master/follower and drive-to-drive communication.
Inactive
Clock synchronization not active.
0
Active
Clock synchronization active.
1
Number of full days passed since beginning of the year 1980.
This parameter, together with
and
makes it possible
to set the date and time in the drive via the parameter
interface from a fieldbus or application program. This may be
necessary if the fieldbus protocol does not support time
synchronization.
-
1…59999
Days since beginning of 1980.
1 = 1
Number of full minutes passed since midnight. For example,
the value 860 corresponds to 2:20 pm.
See parameter
.
0 min
1…1439
Minutes since midnight.
1 = 1
Number of milliseconds passed since last minute.
See parameter
.
0 ms
0…59999
Number of milliseconds since last minute.
1 = 1
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...