Parameters 469
Gray
Gray code.
1
(Visible when an absolute encoder is selected)
Selects the baud rate for an SSI encoder.
10 kBit/s
10 kbit/s.
0
50 kBit/s
50 kbit/s.
1
100 kBit/s
100 kbit/s.
2
200 kBit/s
200 kbit/s.
3
500 kBit/s
500 kbit/s.
4
1000 kBit/s
1000 kbit/s.
5
(Visible when an absolute encoder is selected)
Defines the phase angle within one sine/cosine signal period
that corresponds to the value of zero on the SSI serial link
data. The parameter is used to adjust the synchronization of
the SSI position data and the position based on sine/cosine
incremental signals. Incorrect synchronization may cause an
error of ±1 incremental period.
Note:
This parameter needs to be set only when an SSI
encoder is used in initial position mode (see parameter
315-45 deg
315-45 degrees.
0
45-135 deg
45-135 degrees.
1
135-225 deg
135-225 degrees.
2
225-315 deg
225-315 degrees.
3
(Visible when an absolute encoder is selected)
Defines the use of parity and stop bits with a HIPERFACE
encoder.
Typically this parameter need not be set.
Odd
Odd parity indication bit, one stop bit.
0
Even
Even parity indication bit, one stop bit.
1
(Visible when an absolute encoder is selected)
Defines the transfer rate of the link with a HIPERFACE
encoder.
Typically this parameter need not be set.
4800 bits/s
4800 bit/s.
0
9600 bits/s
9600 bit/s.
1
19200 bits/s
19200 bit/s.
2
38400 bits/s
38400 bit/s.
3
(Visible when an absolute encoder is selected)
Defines the node address for a HIPERFACE encoder.
Typically this parameter need not be set.
64
0…255
HIPERFACE encoder node address.
-
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...