380 Parameters
Displays raw (unmodified) actual value ACT1 sent by fieldbus
adapter B to the master (PLC) if debugging is enabled by
parameter
.
This parameter is read-only.
-
-2147483648 …
2147483647
Raw ACT1 sent by fieldbus adapter B to master.
-
Displays raw (unmodified) actual value ACT2 sent by fieldbus
adapter B to the master (PLC) if debugging is enabled by
parameter
.
This parameter is read-only.
-
-2147483648 …
2147483647
Raw ACT2 sent by fieldbus adapter B to master.
-
Selects the communication time levels.
In general, lower time levels of read/write services reduce
CPU load. The table below shows the time levels of the
read/write services for cyclic high and cyclic low data with
each parameter setting.
* Cyclic high data consists of fieldbus Status word, Act1 and
Act2.
** Cyclic low data consists of the parameter data mapped to
parameter groups
and acyclic data.
Control word, Ref1 and Ref2 are handled as interrupts
generated on receipt of cyclic high messages.
Normal
Normal speed.
0
Fast
Fast speed.
1
Very fast
Very fast speed.
2
Monitoring
Low speed. Optimized for PC tool communication and
monitoring usage.
3
No.
Name/Value
Description
Def
/
FbEq16
Selection
Cyclic high *
Cyclic low **
10 ms
2 ms
2 ms
10 ms
500 µs
2 ms
250 µs
2 ms
Summary of Contents for ACS880-01 Series
Page 1: ...ABB industrial drives Firmware manual ACS880 ESP control program option N5600 ...
Page 4: ......
Page 12: ...12 Table of contents ...
Page 20: ...20 Introduction to the manual ...
Page 22: ...22 Using the control panel ...
Page 28: ...28 Control locations and operating modes ...
Page 146: ...146 Application macros ...
Page 502: ...502 Parameters ...
Page 606: ...606 Fault tracing ...
Page 662: ...662 Control chain diagrams ...