background image

ACS880-01/04 +C132 marine type-approved drives   23

ACS880-01 IP55 (UL Type 12) drive types -274A-2, 293A-3, -247A-4, -260A-5, -
302A-5 and -174A-7

In the temperature range +40…45 °C (+104…113 °F), the rated output current is 
derated by 1% for every added 1 °C (1.8 °F).

In the temperature range +45…55 °C (+113…131 °F), the rated output current is 
derated by 2.5% for every added 1 °C (1.8 °F).

To calculate the output current, multiply the current in the ratings table by the derating 
factor (

k

): 

T

1.00

0.90

+40 °C

+104 °F

+50 °C

+122 °F

k

+55 °C

+131 °F

0.80

+45 °C

+113 °F

0.70

0.75

0.85

0.95

-15 °C

+5 °F

1.05

Summary of Contents for ACS880-01 Series

Page 1: ...ABB SINGLE DRIVES ACS880 01 04 C132 marine type approved drives Supplement...

Page 2: ......

Page 3: ...Supplement ACS880 01 04 C132 marine type approved drives 3AXD50000010521 Rev D EN EFFECTIVE 2018 11 07 2018 ABB Oy All Rights Reserved Table of contents...

Page 4: ......

Page 5: ...ACS880 01 12 Connection procedure ACS880 04 12 Technical data 13 Ratings ACS880 01 C132 13 IEC RATINGS ACS880 01 C132 13 UL NEC RATINGS ACS880 01 C132 16 Definitions ACS880 01 18 Ratings ACS880 04 C13...

Page 6: ...6...

Page 7: ...t to ACS880 01 hardware manual 3AUA0000078093 English and ACS880 04 drive modules hardware manual 3AUA0000128301 English The supplement contains additional instructions and information on the marine t...

Page 8: ...tant control panels user s manual 3AUA0000085685 ACS880 04 drive modules 200 to 710 kW 300 to 700 hp hardware manual 3AUA0000128301 ACS880 04 drive modules 200 to 710 kW 300 to 700 hp quick installati...

Page 9: ...ACS880 01 04 C132 marine type approved drives 9 The codes below open an online listing of the manuals applicable to this product ACS880 01 manuals ACS880 04 manuals...

Page 10: ...he marine environment also marine specific 440 V voltage Some classification agencies require use of a common mode filter option E208 Layout IP21 UL Type 1 The components of the standard IP21 marine t...

Page 11: ...ion dampers for ACS880 01 drives frames R6 to R9 option C131 installation guide 3AXD50000013389 English Cabinet installation of frame sizes R1 to R9 The drive can be installed into a cabinet without v...

Page 12: ...Connection diagram See the hardware manual Connection procedure ACS880 01 1 Install the input power cable and brake resistor cable if present as shown in the hardware manual 2 Install the common mode...

Page 13: ...10 1 12 8 10 1 2 2 9 6 2 2 7 1 1 5 16A8 2 R2 16 0 18 0 16 0 3 0 15 2 3 0 10 1 2 2 24A3 2 R2 23 28 6 23 5 5 21 9 5 5 16 0 4 0 031A 2 R3 29 41 29 7 5 27 8 7 5 23 5 5 046A 2 R4 44 64 44 11 42 11 36 7 5 0...

Page 14: ...132 430A 3 R9 409 545 409 200 380 200 345 160 UN 500 V 02A1 5 R1 2 0 3 1 2 0 0 75 2 0 0 55 1 6 0 55 03A0 5 R1 2 9 4 1 2 9 1 1 2 8 1 1 2 0 0 75 03A4 5 R1 3 2 5 6 3 2 1 1 3 2 1 1 2 9 1 1 04A8 5 R1 4 6...

Page 15: ...8 15 027A 7 R3 26 46 26 22 24 18 5 22 18 5 07A3 7 R5 6 9 12 2 6 9 4 0 6 6 4 0 5 3 3 0 09A8 7 R5 9 3 18 9 3 7 5 8 8 7 5 6 9 4 0 14A2 7 R5 13 5 22 13 5 11 0 12 8 11 9 3 5 5 018A 7 R5 17 29 17 11 16 11 1...

Page 16: ...3 10A4 4 R1 10 4 16 10 4 5 5 7 5 7 2 4 0 5 013A 4 R2 13 21 13 7 5 10 10 5 5 7 5 019A 4 R2 19 29 19 11 15 13 7 5 10 026A 4 R3 26 42 26 15 20 20 11 15 032A 4 R3 32 54 32 18 5 25 26 15 20 038A 4 R4 38 64...

Page 17: ...6 49 30 40 38 22 30 065A 5 R5 62 104 62 37 50 49 30 40 077A 5 R5 73 122 73 45 60 62 37 50 096A 5 R6 91 148 91 55 75 73 45 60 124A 5 R6 118 178 118 75 100 91 55 75 156A 5 R7 148 247 148 90 125 118 75 1...

Page 18: ...000588487 UN Nominal voltage of the drive For the input voltage range see section Electrical power network specification in the hardware manual I1N Nominal rms input current IN Nominal output current...

Page 19: ...The ratings apply at an ambient temperature of 45 C 113 F Note 2 To achieve the rated motor power given in the table the rated current of the drive must be higher than or equal to the rated motor curr...

Page 20: ...820A 3 R11 779 1020 1100 779 400 770 400 594 315 880A 3 R11 836 1100 1100 836 450 822 450 689 355 UN 500 V 460A 5 R10 437 560 671 437 250 428 250 314 200 503A 5 R10 480 560 671 478 315 459 315 343 20...

Page 21: ...300 430A 7 R10 409 540 720 399 355 400 342 315 350 425A 7 R11 404 520 720 394 355 400 342 315 350 470A 7 R11 447 655 830 432 400 450 394 355 400 522A 7 R11 496 685 910 480 450 500 432 400 450 590A 7...

Page 22: ...e every 5 minutes Continuous rms output current allowing 40 overload for 1 minute every 5 minutes Continuous rms output current allowing 44 overload for 1 minute every 5 minutes Continuous rms output...

Page 23: ...the rated output current is derated by 1 for every added 1 C 1 8 F In the temperature range 45 55 C 113 131 F the rated output current is derated by 2 5 for every added 1 C 1 8 F To calculate the out...

Page 24: ...d output current is derated by 1 for every added 1 C 1 8 F In the temperature range 50 55 C 122 131 F the rated output current is derated by 2 5 for every added 1 C 1 8 F To calculate the output curre...

Page 25: ...the temperature range 45 50 C 113 122 F the rated output current is derated by 2 5 for every added 1 C 1 8 F In the temperature range 50 55 C 122 131 F the rated output current is derated by 5 for eve...

Page 26: ...ACS880 01 IP55 UL Type 12 types 0430A 3 393A 4 0414A 5 and 0271A 7 The maximum ambient temperature is 35 C 95 F Applicable standards See the hardware manual Marine type approvals You can find the ACS8...

Page 27: ...e contacts can be found by navigating to abb com searchchannels Product training For information on ABB product training navigate to new abb com service training Providing feedback on ABB Drives manua...

Page 28: ...abb com drives Copyright 2018 ABB All rights reserved Specifications subject to change without notice 3AXD50000010521 Rev D EN 2018 11 07...

Reviews: