Parameters 295
Loading
A user set is being loaded.
1
Saving
A user set is being saved.
2
Faulted
Invalid parameter set.
3
User set 1
User set 1 has been loaded.
4
User set 2
User set 2 has been loaded.
5
User set 3
User set 3 has been loaded.
6
User set 4
User set 4 has been loaded.
7
Enables the saving and restoring of up to four custom sets of
parameter settings. See section
(page
The set that was in use before powering down the drive is in
use after the next power-up.
Notes:
• Hardware configuration settings such as fieldbus and
encoder configuration parameters (groups 14…16, 51…56,
58 and 92…93, and parameters
and
50.31
), and
forced input/output values (such as
) are
not included in user parameter sets.
• Parameter changes made after loading a set are not
automatically stored – they must be saved using this
parameter.
• If no sets have been saved, attempting to load a set will
create all sets from the currently active parameter settings.
• Switching between sets is only possible with the drive
stopped.
No action
Load or save operation complete; normal operation.
0
User set I/O mode
Load user parameter set using parameters
1
Load set 1
Load user parameter set 1.
2
Load set 2
Load user parameter set 2.
3
Load set 3
Load user parameter set 3.
4
Load set 4
Load user parameter set 4.
5
Save to set 1
Save user parameter set 1.
18
Save to set 2
Save user parameter set 2.
19
Save to set 3
Save user parameter set 3.
20
Save to set 4
Save user parameter set 4.
21
No.
Name/Value
Description
Def
/
FbEq16
Summary of Contents for ACS860
Page 1: ... ABB INDUSTRIAL DRIVES ACS860 primary control program Firmware manual ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 18: ...18 Using the control panel ...
Page 24: ...24 Control locations and operating modes ...
Page 54: ...54 Program features ...
Page 78: ...78 Program features ...
Page 90: ...90 Application macros ...
Page 342: ...342 Additional parameter data ...
Page 380: ...380 Fault tracing ...
Page 381: ...Fault tracing 381 ...
Page 382: ...382 Fault tracing ...
Page 436: ...436 Control chain diagrams ...