Parameters 185
52
52 FBA data in
Selection of data to be transferred from drive to fieldbus
controller.
52.01
FBA data in1
select data to be transferred from
the drive to the fieldbus controller.
4
Status Word (16 bits)
4
5
Actual value 1 (16 bits)
5
6
Actual value 2 (16 bits)
6
14
Status Word (32 bits)
14
15
Actual value 1 (32 bits)
15
16
Actual value 2 (32 bits)
16
101…9999
Parameter index
1 = 1
…
…
…
…
52.12
FBA data in12
See parameter
53
53 FBA data out
Selection of data to be transferred from fieldbus controller to
drive.
53.01
FBA data out1
select data to be transferred from
the fieldbus controller to the drive.
1
Control Word (16 bits)
1
2
Reference REF1 (16 bits)
2
3
Reference REF2 (16 bits)
3
11
Control Word (32 bits)
11
12
Reference REF1 (32 bits)
12
13
Reference REF2 (32 bits)
13
101…9999
Parameter index
1 = 1
…
…
…
…
53.12
FBA data out12
See parameter
56
56 Panel display
Selection of signals to be displayed on control panel.
56.01
Signal1 param
Selects the first signal to be displayed on the optional control
panel. The default signal is
.
00.00 … 255.255
1st signal to be displayed.
-
56.02
Signal2 param
Selects the second signal to be displayed on the optional
control panel. The default signal is
.
00.00 … 255.255
2nd signal to be displayed.
-
56.03
Signal3 param
Selects the third signal to be displayed on the optional control
panel. The default signal is
00.00 … 255.255
3rd signal to be displayed.
-
56.04
Signal1 mode
Defines the way the signal selected by parameter
is displayed on the optional control panel.
Disabled
Signal not displayed. Any other signals that are not disabled
are shown together with their respective signal name.
-1
Normal
Shows the signal as a numerical value followed by unit.
0
Bar
Shows the signal as a horizontal bar.
1
No.
Name/Value
Description
FbEq