![ABB ACS850-04 series Firmware Manual Download Page 180](http://html1.mh-extra.com/html/abb/acs850-04-series/acs850-04-series_firmware-manual_3365228180.webp)
180 Parameters
Pt100 Ext x1
The temperature is supervised using a Pt100 sensor
connected to the first available analog input and analog
output on I/O extensions installed on the drive.
10
Pt100 Ext x2
The temperature is supervised using two Pt100 sensors
connected to the first available analog input and analog
output on I/O extensions installed on the drive.
11
Pt100 Ext x3
The temperature is supervised using three Pt100 sensors
connected to the first available analog input and analog
output on I/O extensions installed on the drive.
12
31.07
Mot temp2 almLim
Defines the alarm limit for the motor thermal protection 2
(when parameter
is set to either
0 … 200 °C
Motor overtemperature alarm limit.
1 = 1 °C
31.08
Mot temp2 fltLim
Defines the fault limit for the motor thermal protection 2 (when
parameter
0 … 200 °C
Motor overtemperature fault limit.
1 = 1 °C
31.09
Mot ambient temp
Defines the ambient temperature for the thermal protection
mode.
-60 … 100 °C
Ambient temperature.
1 = 1 °C
31.10
Mot load curve
Defines the load curve together with parameters
and
When the parameter is set to 100%, the maximum load is
equal to the value of parameter
(higher loads heat up the motor). The load curve level should
be adjusted if the ambient temperature differs from the
nominal value.
The load curve is used by the motor thermal protection model
when parameter
.
50 … 150%
Maximum load for the motor load curve.
1 = 1%
No.
Name/Value
Description
FbEq
50
100
150
I/I
N
(%)
I
= Motor current
I
N
= Nominal motor current
Drive output
frequency
Summary of Contents for ACS850-04 series
Page 1: ...ACS850 Firmware Manual ACS850 Standard Control Program...
Page 4: ......
Page 10: ...10 Table of contents...
Page 52: ...52 The ACS850 control panel...
Page 56: ...56 Control locations and operating modes...
Page 80: ...80 Program features...
Page 236: ...236 Parameters...
Page 286: ...286 Fieldbus control...
Page 294: ...294 Control block diagrams...