128 Technical data
DC resistor connection data
See
ABRU-0x DC choppers (+D150) and resistors (+D151) for ACS800-67LC/-77LC/-
87LC wind turbine converters hardware manual
[3AUA0000076494 (English)].
DC connection data
Efficiency
System efficiency is at least 97% at rated current and nominal supply voltage (generator
dependent).
Degree of protection
IP54 as standard. UL Type 12 is available as an option (+C129).
Ambient conditions
Nominal voltage
976 V DC +20%
Maximum operating voltage
< 1211 V DC
DC voltage limits
Overvoltage: 136% x
U
DC
Undervoltage: 50% x
U
DC
Current
See section
Environmental limits for the converter are given below. The converter must be
used in a specified environment.
Operation
installed for stationary use
Storage
in the protective package
Transportation
in the protective package
Installation site altitude
0 to 2000 m (6562 ft)
above sea level. Above
1000 m (3281 ft), see
section
on page
-
-
Air temperature
-30 to +55 °C (-22 to
131 °F). Above +45 °C
(+113 °F), see section
on page
frost allowed.
Note:
UL temperature
requirement: max. +40 °C
(+104 °F).
-40 to +70 °C (-40 to
+158 °F)
-40 to +70 °C (-40 to
+158 °F)
Water temperature
See section
on page
.
Relative humidity
5 to 95%
Max. 95%
Max. 95%
No condensation allowed. Maximum allowed relative humidity is 60% in the
presence of corrosive gases.
Contamination levels
(IEC 60721-3-3,
IEC 60721-3-2,
IEC 60721-3-1)
No conductive dust allowed.
Boards with coating:
Chemical gases: Class
3C2
Solid particles: Class 3S2
Boards with coating:
Chemical gases: Class
1C2
Solid particles: Class 1S3
Boards with coating:
Chemical gases: Class
2C2
Solid particles: Class 2S2
Atmospheric pressure
70 to 106 kPa
0.7 to 1.05 atmospheres
70 to 106 kPa
0.7 to 1.05 atmospheres
60 to 106 kPa
0.6 to 1.05 atmospheres
Summary of Contents for ACS800-67LC
Page 1: ... ABB WIND TURBINE CONVERTERS ACS800 67LC wind turbine converters Hardware manual ...
Page 4: ......
Page 16: ...16 Safety instructions ...
Page 22: ...22 Introduction to the manual ...
Page 42: ...42 Operation principle and hardware description ...
Page 52: ...52 Mechanical installation ...
Page 79: ...Electrical installation 79 3 3 Rotor side cable connection terminals U2 V2 W2 ...
Page 92: ...92 Maintenance 4 6 5 5 ...
Page 103: ...Maintenance 103 Bussmann fuses Mersen fuses ...
Page 109: ...Maintenance 109 5 6 7 ...
Page 131: ...Technical data 131 Declaration of incorporation ...
Page 136: ...136 Dimension drawings ACS800 67LC 1075 0575 7 and 1375 0575 7 ...
Page 137: ...Dimension drawings 137 With 400 mm wide incoming cubicle option C111 ...
Page 138: ...138 Dimension drawings ACS800 67LC 1375 1125 7 ...
Page 139: ...Dimension drawings 139 With 400 mm wide incoming cubicle option C111 ...
Page 140: ...140 Dimension drawings ACS800 67LC 1595 0865 7 and 2035 1125 7 ...
Page 141: ...Dimension drawings 141 With 400 mm wide incoming cubicle option C111 ...
Page 143: ...Dimension drawings 143 Options 2H370 and C111 Option 1H371 ...
Page 144: ...144 Dimension drawings Options 1H371 and C111 Options 2H371 and C111 ...
Page 145: ...Dimension drawings 145 Option H378 Options H378 and C111 ...
Page 147: ...Dimension drawings 147 Option 2H372 ...
Page 148: ...148 Dimension drawings Option 3H372 ...
Page 149: ...Dimension drawings 149 Option 1H373 ...
Page 150: ...150 Dimension drawings Option 2H373 ...
Page 151: ...Dimension drawings 151 Option 3H373 ...