Technical data
101
US tables
NEMA ratings
The NEMA ratings for the ACS800-U2 with 60 Hz supplies are given below. The
symbols are described below the table. For sizing, derating and 50 Hz supplies, see
.
1)
available if ambient temperature is less than 30 °C (86 °F). If ambient temperature is 40 °C (104 °F),
I
2N
is 286 A.
2)
special 4-pole high-efficiency NEMA motor
3)
50 % overload is allowed for one minute every five minutes if ambient temperature is less than
30 °C. 40 % overload is allowed if ambient temperature is 40 °C.
4)
available if ambient temperature is less than 30 °C (86 °F). If ambient temperature is 40 °C
(104 °F),
I
2N
is 704 A.
ACS800-U2 size
I
max
Normal use
Heavy-duty use
Frame
size
Air flow
Heat
dissipation
A
I
2N
A
P
N
HP
I
2hd
A
P
hd
HP
ft
3
/min
BTU/Hr
Three-phase supply voltage 208 V, 220 V,
230 V
or 240 V
-0080-2
326
211
75
170
60
R7
318
9900
-0100-2
404
248
100
202
75
R7
318
11750
-0120-2
432
290
100
240
4)
75
R7
318
13750
-0140-2
588
396
150
316
125
R8
718
16450
-0170-2
588
440
150
340
125
R8
718
20800
-0210-2
588
516
200
370
150
R8
718
22750
-0230-2
840
598
200
480
200
R8
718
25900
-0260-2
1017
679
250
590
2)
200
R8
718
26750
-0300-2
1017
704
250
635
3)
250
R8
718
28300
Three-phase supply voltage 380 V, 400 V, 415 V, 440 V, 460 V, 480 V
-0170-5
326
192
150
162
125
R7
318
10300
-0210-5
384
240
200
192
150
R7
318
13050
-0260-5
432
289
1)
250
2)
224
150
R7
318
15500
-0270-5
480
316
250
240
200
R8
718
15330
-0300-5
568
361
300
302
250
R8
718
18070
-0320-5
588
435
350
340
250
R8
718
23400
-0400-5
588
510
400
370
300
R8
718
26800
-0440-5
840
545
450
490
400
R8
718
25950
-0490-5
840
590
500
515
3)
450
R8
718
27600
-0550-5
1017
670
550
590
3)
500
R8
718
31100
-0610-5
1017
718
4)
600
590
3)
500
R8
718
33000
PDM code: 00096931-G
Summary of Contents for ACS800-02
Page 1: ...ACS800 Hardware Manual ACS800 02 Drives 45 to 500 kW ACS800 U2 Drives 60 to 600 HP ...
Page 4: ......
Page 10: ...Safety instructions 10 ...
Page 20: ...About this manual 20 ...
Page 26: ...The ACS800 02 U2 26 ...
Page 42: ...Planning the electrical installation 42 ...
Page 76: ...Installation checklist 76 ...
Page 106: ...Technical data 106 ...
Page 108: ...Dimensional drawings 108 Frame size R7 US gland conduit plate 64579746 H ...
Page 109: ...Dimensional drawings 109 Frame size R8 3AFE 64564161 D US gland conduit plate ...
Page 110: ...Dimensional drawings 110 Frame size R7 with enclosure extension bottom entry 64625942 1 2 B ...
Page 111: ...Dimensional drawings 111 64625942 2 2 C ...
Page 112: ...Dimensional drawings 112 Frame size R7 with enclosure extension top entry 64626264 1 2 C ...
Page 113: ...Dimensional drawings 113 64626264 2 2 C ...
Page 115: ...Dimensional drawings 115 3AFE 64626388 2 2 B ...
Page 116: ...Dimensional drawings 116 Frame size R8 with enclosure extension top entry 3AFE 64626370 1 2 C ...
Page 117: ...Dimensional drawings 117 3AFE 64626370 2 2 C ...
Page 118: ...Dimensional drawings 118 ...
Page 127: ......