Parameters 225
Source selection (see
). -
Defines a low-pass filter time constant for the torque
reference.
0.000 s
0.000…30.000 s
Filter time constant for torque reference.
1000 = 1 s
Defines the torque reference ramp-up time, ie. the time for the
reference to increase from zero to nominal motor torque.
0.000 s
0.000…60.000 s
Torque reference ramp-up time.
100 = 1 s
Defines the torque reference ramp-down time, ie. the time for
the reference to decrease from nominal motor torque to zero.
0.000 s
0.000…60.000 s
Torque reference ramp-down time.
100 = 1 s
.
Not selected
None.
0
Torque ref torq ctrl
Torque reference from the torque chain.
1
Source selection (see
). -
Torque reference speed control
Not selected
None.
0
Torque ref speed
ctrl
Torque reference from the speed chain.
1
Source selection (see
). -
Displays the value of torque reference source 1 (selected by
parameter
). See the control chain
diagram on page
.
This parameter is read-only.
-
-1600.0…1600.0%
Value of torque reference source 1.
See par.
Displays the value of torque reference source 2 (selected by
parameter
). See the control chain
diagram on page
.
This parameter is read-only.
-
-1600.0…1600.0%
Value of torque reference source 2.
See par.
Displays the torque reference after the function applied by
parameter
(if any), and after
selection (
). See the control
chain diagram on page
.
This parameter is read-only.
-
-1600.0…1600.0%
Torque reference after selection.
See par.
Displays the torque reference after application of reference
additive 1. See the control chain diagram on page
.
This parameter is read-only.
-
-1600.0…1600.0%
Torque reference after application of reference additive 1.
See par.
No.
Name/Value
Description
Def/FbEq16