![ABB ACS580-04 Hardware Manual Download Page 179](http://html.mh-extra.com/html/abb/acs580-04/acs580-04_hardware-manual_2579179.webp)
Note:
•
To achieve the rated motor power given in the table, the rated current of the drive
must be higher than or equal to the rated motor current. The power ratings apply
to most IEC 34 motors at the nominal voltage of the drive.
•
ABB recommends to select the drive, motor and gear combination for the required
motion profile with the DriveSize dimensioning tool available from ABB.
Output derating
■
When is derating necessary?
The output load capacity (
I
2
,
I
Ld
,
I
Hd
) decreases when the drive is installed into a high
altitude or high temperature environment, and also when the application requires a
high minimum switching frequency. In an environment where more than one type of
derating is necessary (for example, high altitude and high temperature), the effects
of derating are cumulative. If necessary, oversize the drive so that the total derated
output current is sufficient for the motor to reach the full power.
Note:
•
The motor can also have a derating on it.
•
You can also use the DriveSize tool
(
http://new.abb.com/drives/software-tools/drivesize
) for derating.
Example 1, IEC: How to calculate the derated current
The IP00 drive type is ACS580-04-725A-4, which has drive output current of 725 A.
Calculate the derated drive output current (
I
2
) at 4 kHz switching frequency, at 1500 m
altitude and at 50 °C surrounding air temperature as follows:
1.
Switching frequency derating (page 181)
:
The derating factor for 4 kHz switching frequency is 0.78. The derated drive output
current then becomes:
I
2
= 0.78 · 725 A = 565.5 A
2.
:
The derating factor for 1500 m is 1 - 1/10 000 m · (1500 - 1000) m = 0.95. The
derated drive output current then becomes:
I
2
= 0.95 · 565.5 A = 537.2 A.
3.
Surrounding air temperature derating (page 180)
:
The derating factor for 50 °C ambient temperature is 0.90. The derated drive
output current then becomes:
I
2
= 0.90 · 575.2 A = 483.5 A.
Example 2, IEC: How to calculate the required drive
If your application requires continuous 585 A of motor current (
I
2
) at 4 kHz switching
frequency, the supply voltage is 400 V and the drive is situated at 1500 m altitude and
at 35 °C surrounding air temperature, calculate the appropriate IP00 drive size
requirement as follows:
1.
Switching frequency derating (page 181)
:
The minimum size required is
I
2
= 585 A / 0.78 = 750 A, where 0.78 is the derating
for 4 kHz switching frequency.
2.
:
Technical data 179
Summary of Contents for ACS580-04
Page 1: ... ABB GENERAL PURPOSE DRIVES ACS580 04 drive modules Hardware manual ...
Page 2: ......
Page 4: ......
Page 26: ...26 ...
Page 60: ...60 ...
Page 69: ...2 1 Tapping screw M6 12 Torx T30 Hex 9 N m 6 6 lbf ft Mechanical installation 69 10 ...
Page 72: ...72 ...
Page 100: ...100 ...
Page 120: ...120 ...
Page 128: ...2 7a 7b 5 3 3 7a 7b 8a 8b 8b 4 128 Installation example with full cabling panels option H381 ...
Page 133: ...Installation example with full cabling panels option H381 133 ...
Page 134: ...134 ...
Page 146: ...146 ...
Page 157: ...External control unit option P906 157 ...
Page 162: ...162 ...
Page 164: ...164 ...
Page 200: ...R10 standard configuration 200 Dimension drawings ...
Page 201: ...R10 with options E208 0H354 H356 H370 0H371 Dimension drawings 201 ...
Page 202: ...R10 with option B051 202 Dimension drawings ...
Page 203: ...R10 with options E208 H356 P906 Dimension drawings 203 ...
Page 204: ...R10 with options E208 0H371 H356 0H354 H370 P906 204 Dimension drawings ...
Page 205: ...R10 with options B051 P906 Dimension drawings 205 ...
Page 208: ...R11 standard configuration 208 Dimension drawings ...
Page 209: ...R11 with options E208 0H371 H356 0H354 H370 Dimension drawings 209 ...
Page 210: ...R11 with option B051 210 Dimension drawings ...
Page 211: ...R11 with options E208 H356 P906 Dimension drawings 211 ...
Page 212: ...R11 with options E208 0H371 H356 0H354 H370 P906 212 Dimension drawings ...
Page 213: ...R11 with options B051 P906 Dimension drawings 213 ...
Page 248: ...248 ...
Page 260: ...260 ...
Page 265: ...CHDI 01 115 230 V digital input extension module 265 ...
Page 266: ...266 ...
Page 272: ...272 CMOD 01 multifunction extension module external 24 V AC DC and digital I O ...
Page 278: ...278 ...
Page 280: ...280 ...