Ambient conditions
Environmental limits for the drive are given below. The drive is to be used in a heated indoor
controlled environment.
Operation
installed for
stationary use
Storage
in the protective
package
Transportation
in the protective
package
Installation site altitude 230 V units:
0 to
2000 m above sea
level (with derating
above 1000 m)
400 V units:
0 to
4000 m above sea
level (with derating
above 1000 m)
For more information,
refer to page
-
-
Surrounding air
temperature
-10…+60 °C
(14…140 °F)
(1
No frost allowed.
Refer to
on
page
.
1) For frame R0,
-10…+50 °C
(14…122 °F).
-40…+70 °C ±2%
(-40…+158 °F ±2%)
-40…+70 °C ±2%
(-40…+158 °F ±2%)
Relative humidity
0…95%
Max. 95%
Max. 95%
No condensation allowed. Maximum allowed relative humidity is
60% in the presence of corrosive gases.
Contamination levels
(IEC 60721-3-3,
IEC 60721-3-2,
IEC 60721-3-1)
No conductive dust allowed.
According to
IEC 60721-3-3,
chemical gases:
Class 3C2
solid particles:
Class 3S2.
Install the drive
according to the
enclosure
classification.
Make sure that the
cooling air is clean,
and free from
corrosive materials
and electrically
conductive dust.
According to
IEC 60721-3-1,
chemical gases:
Class 1C2
solid particles:
Class 1S2
According to
IEC 60721-3-2,
chemical gases:
Class 2C2
solid particles:
Class 2S2
Pollution degree
(IEC/EN 61800-5-1)
Pollution degree 2
-
-
Summary of Contents for ACS380 Series
Page 1: ...ABB MACHINERY DRIVES ACS380 drives Hardware manual...
Page 4: ......
Page 12: ...12 Table of contents...
Page 20: ...20 Safety instructions...
Page 46: ...46 Mechanical installation...
Page 60: ...60 Planning the electrical installation...
Page 86: ...86 Maintenance...
Page 120: ...120 Technical data...
Page 122: ...122 Dimension drawings Frame R0 1 phase 230 V...
Page 123: ...Dimension drawings 123 Frame R0 400 V...
Page 124: ...124 Dimension drawings Frame R1 230 V...
Page 125: ...Dimension drawings 125 Frame R1 3 phase 230 V and 3 phase 400 V...
Page 126: ...126 Dimension drawings Frame R2 230 V...
Page 127: ...Dimension drawings 127 Frame R2 400 V...
Page 128: ...128 Dimension drawings Frame R3 400 V...
Page 129: ...Dimension drawings 129 Frame R4 400 V...
Page 130: ...130 Dimension drawings...
Page 138: ...138 Resistor braking...
Page 169: ...BTAC 02 pulse encoder interface module 169 Dimensions 3AXD50000031154 rev A...