196 Actual signals and parameters
COMM+AI1
Summation of fieldbus reference REF1 and analog input AI.
See section
Reference selection and correction
on page
9
COMM*AI1
Multiplication of fieldbus reference REF1 and analog input
AI1. See section
Reference selection and correction
on
10
DI3U,4D(RNC) Digital input DI3: Reference increase. Digital input DI4:
Reference decrease. Stop command resets the reference to
zero.
The reference is not saved if the control source is changed
(from EXT1 to EXT2, from EXT2 to EXT1 or from LOC to
REM). Parameter
defines the rate
of the reference change.
11
DI3U,4D(NC)
Digital input DI3: Reference increase. Digital input DI4:
Reference decrease.
The program stores the active speed reference (not reset by
a stop command). The reference is not saved if the control
source is changed (from EXT1 to EXT2, from EXT2 to EXT1
or from LOC to REM). When the drive is restarted, the motor
ramps up at the selected acceleration rate to the stored
reference. Parameter
defines the
rate of the reference change.
12
AI1+AI2
Reference is calculated with the following equation:
REF = AI1(%) + AI2(%) - 50%
14
AI1*AI2
Reference is calculated with the following equation:
REF = AI1(%) · (AI2(%) / 50%)
15
AI1-AI2
Reference is calculated with the following equation:
REF = AI1(%) + 50% - AI2(%)
16
AI1/AI2
Reference is calculated with the following equation:
REF = AI1(%) · (50% / AI2 (%))
17
KEYPAD(RNC) Defines the control panel as the reference source. Stop
command resets the reference to zero (the R stands for
reset). The reference is not copied if the control source is
changed (from EXT1 to EXT2, from EXT2 to EXT1).
20
KEYPAD(NC)
Defines the control panel as the reference source. Stop
command does not reset the reference to zero. The
reference is stored. The reference is not copied if the control
source is changed (from EXT1 to EXT2, from EXT2 to
EXT1).
21
DI4U,5D
See selection
30
DI4U,5D(NC) See
.
31
FREQ INPUT
Frequency input
32
All parameters
No.
Name/Value
Description
Def/FbEq
Summary of Contents for ACS355 series
Page 1: ...ABB machinery drives User s manual ACS355 drives ...
Page 4: ......
Page 16: ...16 ...
Page 32: ...32 Operation principle and hardware description ...
Page 58: ...58 Electrical installation ...
Page 74: ...74 Start up control with I O and ID run ...
Page 106: ...106 Control panels ...
Page 120: ...120 Application macros ...
Page 178: ...178 Program features ...
Page 338: ...338 Fieldbus control with embedded fieldbus ...
Page 368: ...368 Fault tracing ...
Page 404: ...404 Dimension drawings ...
Page 410: ...410 Appendix Resistor braking ...
Page 434: ...434 Appendix Permanent magnet synchronous motors PMSMs ...