106 Parameters
Constant speed/frequency status word. Indicates
which constant speed or frequency is active (if any).
See also parameter
06.19 Speed control status word
,
bit 7, and section Constant speeds/frequencies.
This parameter is read-only.
-
0000h…FFFFh
Constant speed/frequency status word.
1 = 1
Drive status word 3.
This parameter is read-only.
-
0000h…FFFFh
Drive status word 1.
1 = 1
Selects a binary source whose status is transmitted
False
0.
0
True
1.
1
Above limit
Bit 10 of
2
Source selection (see
).
-
Selects a binary source whose status is transmitted
as bit 11 (User bit 0) of
False
0.
0
True
1.
1
Ext ctrl loc
Bit 11 of
2
Source selection (see
).
-
Selects a binary source whose status is transmitted
as bit 12 (User bit 1) of
False
0.
0
True
1.
1
Ext run enable
Status of the external run enable signal (see
2
No.
Name/Value
Description
Default
FbEq 16
Bit
Name
Description
0
Constant speed 1
1 = Constant speed or frequency 1 selected
1
Constant speed 2 1 = Constant speed or frequency 2 selected
2
Constant speed 3 1 = Constant speed or frequency 3 selected
3
Constant speed 4 1 = Constant speed or frequency 4 selected
4
Constant speed 5 1 = Constant speed or frequency 5 selected
5
Constant speed 6 1 = Constant speed or frequency 6 selected
6
Constant speed 7 1 = Constant speed or frequency 7 selected
7…15
Reserved
Bit
Name
Description
0
DC hold active
1 = DC hold is active
1
Post-magnetizing active
1 = Post-magnetizing is active
2
Motor pre-heating active
1 = Motor pre-heating is active
3
PM smooth start active
1 = PM smooth start is active
4
Rotor position known
1 = Rotor position is known
5
DC brake active
1 = DC brake is active
6…15
Reserved
Summary of Contents for ACS280
Page 1: ... ABB MACHINERY DRIVES ACS280 coldplate drives Firmware manual ...
Page 4: ......
Page 10: ...10 ...
Page 16: ...16 Control panel ...
Page 20: ...20 Start up ID run and use ...
Page 24: ...24 Default control connection ...
Page 88: ...88 Program features ...
Page 298: ...298 Parameters ...