67
ACS2000 AFE 2MVA UM
3BHS355653 ZAB E01 REV. H
Location
The fieldbus adapter is DIN rail-mounted inside the
control compartment
.
The indicated mounting position may vary depend-
ing on the number of optional devices present on
the swing frame.
3.3.6 Pulse encoder interface NTAC (option)
Overview
The pulse encoder is required for constant torque
applications.
Communication with AMC circuit board
The NTAC module communicates with the AMC cir-
cuit board of the INU via a fast optical link using
the standard DDCS protocol. The optical fibers are
connected to channel 1 of the AMC circuit board.
Location
The NTAC interface is DIN rail-mounted inside the
control compartment
.
The indicated mounting position may vary depend-
ing on the number of optional devices present on
the swing frame.
—
References
—
3-10 Location of fieldbus
and pulse encoder
interface
—
1
2
Terminals X1
Terminals X2
1
A+
Channel A
1
-V
0 V
2
A-
2
-V
24 V
3
B+
Channel B
3
+V
4
B-
4
24 / 25
5
Z+
Channel Z
5
15
6
Z-
6
24
7
SH
Shield
7
0 V
8
SH
8
+24 V
Summary of Contents for ACS2000 AFE 2MVA
Page 8: ...General information on manual and equipment ...
Page 13: ...13 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Page 14: ...Terms abbreviations trademarks ...
Page 19: ...19 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Page 20: ...Important note on main circuit breaker ...
Page 48: ...Chapter 3 Control system 49 Control unit 50 Main components 55 I O interfaces ...
Page 69: ...69 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Page 111: ...111 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Page 118: ...Commissioning check list ...
Page 153: ...153 ACS2000 AFE 2MVA UM 3BHS355653 ZAB E01 REV H ...
Page 180: ......