276 Parameters
Enables the use of the motor disconnect switch, or selects
the source for the enable signal. When enabled, the drive
does not trip to a fault when it detects the disconnection
but remains operational and returns to normal operation
after a reconnection.
When this parameter is enabled, the drive will go through
the following sequence:
1. Motor is disconnected: Drive detects the disconnection
and indicates it with warning
. The drive remains
in operation and waits for motor reconnection.
2. Motor is reconnected: Drive detects the reconnection,
removes the warning and returns to normal operation.
The last active reference before the disconnection is in
use.
Note
: This feature is only available in scalar mode. This
parameter does not affect vector mode behavior.
0
Disable.
1 = 1
1
Enable.
1 = 1
Change the cooling fan control mode
Auto
Cooling fan is controlled automatically
0
Always on
Cooling fan is always running
1
96
Language selection; access levels; macro selection;
parameter save and restore; control unit reboot; user
parameter sets; unit selection; parameter checksum
calculation; user lock.
Selects the language of the parameter interface and other
displayed information when viewed on the control panel.
Notes:
• Not all languages listed below are necessarily
supported.
• This parameter does not affect the languages visible in
the Drive composer PC tool. (Those are specified
under
View
–
Settings
–
Drive default language
.)
Not selected
Select a language.
0
English
English.
1033
Deutsch
German.
1031
Italiano
Italian.
1040
Español
Spanish.
3082
Portugues
Portuguese.
2070
Nederlands
Dutch.
1043
Français
French.
1036
Suomi
Finnish.
1035
Svenska
Swedish.
1053
Russki
Russian.
1049
Polski
Polish.
1045
Türkçe
Turkish.
1055
Chinese (Simplified,
PRC)
Simplified Chinese.
2052
No.
Name/Value
Description
Default
FbEq 16