134 Parameters
Defines the real internal value that corresponds to the
minimum analog input AI1 value defined by parameter
. (Changing the polarity settings of
and
can effectively invert the analog input.)
0
-32768.000…
32767.000
1 = 1
Defines the real internal value that corresponds to the
maximum analog input AI1 value defined by parameter
. See the drawing at parameter
.
50.000
-32768.000…
32767.000
Real value corresponding to maximum AI1 value.
1 = 1
Displays the value of analog input AI2 in mA or V
(depending on whether the input is set to current or
voltage by a hardware setting).
This parameter is read-only.
-
0.000…22.000 mA
or 0.000…11.000 V
Value of analog input AI2.
1000 = 1 mA
or V
Displays the value of analog input AI2 after scaling. See
parameters
and
.
This parameter is read-only.
-
-32768.000…
32767.000
Scaled value of analog input AI2.
1 = 1
Forced value that can be used instead of the true reading
of the input. See parameter
.
-
0.000…22.000 mA
or 0.000…11.000 V
Forced value of analog input AI2.
1000 = 1 mA
or V
Selects the unit for readings and settings related to analog
input AI2. See the default control connections of the
macro in use, in chapter
(page
mA
V
Volts.
2
mA
Milliamperes.
10
No.
Name/Value
Description
Default
FbEq 16
AI
in
AI
scaled
(
)