PREVENTIVE AND CORRECTIVE MAINTENANCE
PRODUCT
ACS1000W
DOCUMENT KIND
User manual
DOCUMENT ID.
3BHS213400 E01
REV.
J
LANG.
en
PAGE
162/166
Procedure
1.
Disconnect all power supplies to the drive and ground the drive.
For more information, see
Section 11.6.2 De-energizing the drive locally
2.
Disconnect and remove the power supply cable from the terminal box
(1 in Fig. 11
8) inside the water cooling cabinet.
Figure 11
-
9 Water cooling unit – replacing the internal fan
3.
Unscrew the cover of the fan housing (2 in Fig. 11
8).
4.
Unscrew the fixing bolts on the underside of the fan (1 in Fig. 11
9).
IMPORTANT!
If the fan is equipped with a baffle blade louver (2 in Fig. 11
9),
secure the baffle blade louver against dropping before you remove the bolts.
5.
Install the new fan in reverse order of removal.
1) Fixing bolt location
2) Baffle blade louver
3) 1/4”
4) 70 mm
5) 13 mm
1
2
3
4
5