Fieldbus control
276
03.33 CRANE FAULT WORD
03.34 APPL CONTROL WORD
03.36 M F STATUS WORD
Bit
Name
Description
0
MOTOR OVER SPD
For the possible causes and remedies, see chapter
.
1
SPD MATCH FLT
For the possible causes and remedies, see chapter
.
2
TRQ PROVE FLT
For the possible causes and remedies, see chapter
.
3
BRAKE SLIP FLT
For the possible causes and remedies, see chapter
.
4
SYNC FAULT
For the possible causes and remedies, see chapter
.
5
INV LIMIT
For the possible causes and remedies, see chapter
.
6
SAFETY CLS FLT
For the possible causes and remedies, see chapter
.
7 … 15
Reserved
Bit
Name
Description
0
SYNC ENABLE
Used when selection of Par 10.14 is COMM.MODULE.
Bit = 1 Synchro command is active, Bit = 0 Synchro
command is inactive. See Par.
.
1
HOMING ACK
Used when selection of Par. 10.15 is COMM.MODULE.
Bit = 1; Homing Ackn command is active, Bit = 0; Homing
Ackn command is inactive. A pulse signal is required for
initializing the position value. See Par.
.
2 … 15
Not Used
Bit
Name
Description
0
STANDBY
The drive is configured as standby. See Par.
.
1
STANDALONE IN M/F
The drive is configured as Master or Follower but not in
EXT2 control
2
ACTIVE MASTER
The drive is configured as Master and in EXT2 control
3
ACTIVE FOLLOWER
The drive is configured as Follower and in EXT2 control
4
SYNC FOLLOWER
The drive is configured as Follower, in EXT2 control and in
shaft synchronisation mode
5 … 15
Not Used
Summary of Contents for ACS 800 Series
Page 1: ...ACS800 Firmware Manual Crane Control Program N697 ...
Page 4: ......
Page 26: ...Start up and control through the I O interface 26 ...
Page 36: ...Quick start up guide 36 ...
Page 52: ...Control panel 52 ...
Page 105: ...Program features 105 Figure Control diagram for Shaft synchronisation executed in 20 ms ...
Page 128: ...Program features 128 ...
Page 150: ...Application macros control location EXT1 EXT2 150 ...
Page 228: ...Actual signals and parameters 228 ...
Page 299: ...Adaptive Programming examples for crane control 299 ...
Page 305: ...Adaptive Programming examples for crane control 305 ...
Page 318: ...Analogue Extension Module 318 ...
Page 332: ...Additional data actual signals and parameters 332 ...
Page 334: ...DriveWindow 334 ...
Page 335: ...Control block diagrams 335 Control block diagrams ...
Page 336: ...Control block diagrams 336 ...
Page 337: ...Control block diagrams 337 ...
Page 338: ...Control block diagrams 338 ...
Page 340: ...www abb com drives www abb com drivespartners Contact us 3AFE68775230 Rev E EN 2012 09 25 ...