Chapter 4 – Electrical Installation
Installation and Start-up Guide for NBRA-6xx
4-7
Power Connections
NBRA-654/664
WARNING!
Before installation, switch off the mains supply to the
ACS 600. Wait five minutes to ensure that the intermediate circuit is
discharged. Switch off all dangerous voltages connected to the inputs
or the outputs of the ACS 600.
Figure 4-4
Top:
NBRA-654/664 power connections.
Bottom:
Earthing connections.
ACS 600
U2
V2
W2
U1
V1
W1
1
2
3
UDC+
UDC
–
NBRA-6x4
R–
R+
R
Braking Resistor
R–
R+
PE
Copper Sleeve
Screen Earthing Clamp
2
3
3
2
1
1
Screen Earthing Clamp