Parameters 145
13.14
AI3 max scale
Defines the real value that corresponds to the maximum
analog input AI3 value defined by parameter
-32768.000 …
32768.000
Real value corresponding to maximum AI3 value.
1000 = 1
13.15
AI3 min scale
Defines the real value that corresponds to the minimum
analog input AI3 value defined by parameter
See the drawing at parameter
.
-32768.000 …
32768.000
Real value corresponding to minimum AI3 value.
1000 = 1
13.16
AI4 filt time
Defines the filter time constant for analog input AI4. See
parameter
.
0.000 … 30.000 s
Filter time constant.
1000 = 1 s
13.17
AI4 max
Defines the maximum value for analog input AI4. The input
type depends on the type and/or settings of the I/O
extension module installed. See the user documentation of
the extension module.
-22.000 … 22.000
mA or
-11.000 … 11.000 V
AI4 maximum value.
1000 = 1 unit
13.18
AI4 min
Defines the minimum value for analog input AI4. The input
type depends on the type and/or settings of the I/O
extension module installed. See the user documentation of
the extension module.
-22.000 … 22.000
mA or
-11.000 … 11.000 V
AI4 minimum value.
1000 = 1 unit
No.
Name/Value
Description
FbEq
AI
(scaled)
AI
(mA/V)
Summary of Contents for ACQ810
Page 1: ...ABB industrial drives Firmware manual Standard pump control program for ACQ810 drives ...
Page 4: ......
Page 14: ...14 About the manual ...
Page 56: ...56 Control locations ...
Page 97: ...Application macros 97 ...
Page 98: ...98 Application macros ...
Page 100: ...100 Application macros ...
Page 101: ...Application macros 101 ...
Page 106: ...106 Application macros 75 01 Operation mode Multipump 76 01 Enable MF comm Yes ...
Page 356: ...356 Control through the embedded fieldbus interface ...
Page 366: ...366 Control through a fieldbus adapter ...
Page 374: ...374 Control block diagrams ...