Fault tracing 323
2310
Overcurrent
Output current has
exceeded internal fault
limit.
In addition to an actual
overcurrent situation,
this fault may also be
caused by an earth fault
or supply phase loss.
Check motor load.
Check acceleration times in
parameter group
(speed control) or
(frequency control). Also check
parameter
.
Check motor and motor cable
(including phasing and delta/star
connection).
Check there are no contactors
opening and closing in motor
cable.
Check that the startup data in
parameter group 99 corresponds
to the motor rating plate.
Check that there are no power
factor correction capacitors or
surge absorbers in motor cable.
Check for an earth fault in motor
or motor cables by measuring the
insulation resistances of motor
and motor cable. See chapter
Electrical installation
, section
Checking the insulation of the
assembly
in the
Hardware manual
of the drive.
2330 Earth leakage
Programmable fault:
Drive has detected load
unbalance typically due
to earth fault in motor or
motor cable.
Check there are no power factor
correction capacitors or surge
absorbers in motor cable.
Check for an earth fault in motor
or motor cables by measuring the
insulation resistances of motor
and motor cable.
Try running the motor in scalar
control mode if allowed. (See
parameter
.)
If no earth fault can be detected,
contact your local ABB
representative.
Code
(hex)
Fault / Aux. code
(
aux code visible only on
assistant control panel
and drive composer)
Cause
What to do
Summary of Contents for ACQ80
Page 1: ... ABB DRIVES FOR WATER ACQ80 standard program control Firmware manual ...
Page 2: ... Related documents are listed on page 13 ...
Page 4: ......
Page 10: ...10 Table of contents ...
Page 32: ...32 Startup control with I O and ID run ...
Page 34: ...34 Using the control panel ...
Page 74: ...74 Program features ...
Page 78: ...78 Control macros ...
Page 380: ...380 Fieldbus control through a fieldbus adapter ...
Page 384: ...384 Parameterization with Drive Composer ...
Page 388: ...388 Parameterization with Automation builder drive manager ...