Program features 77
DC hold
The function makes it possible to lock the rotor at (near) zero speed in the middle of
normal operation. DC hold is activated by parameter
. When
both the reference and motor speed drop below a certain level (parameter
), the drive will stop generating sinusoidal current and start to inject DC
into the motor. The current is set by parameter
. When the
reference exceeds parameter
, normal drive operation
continues.
Settings
Parameters
and
.
Post-magnetization
The function keeps the motor magnetized for a certain period (parameter
) after stopping. This is to prevent the machinery from moving
under load, for example before a mechanical brake can be applied. Post-
magnetization is activated by parameter
. The magnetization
Note:
Post-magnetization is only available when ramp stop is selected (see
parameter
). Post-magnetization is only supported in vector control.
Settings
Parameters
(page
Reference
Motor speed
DC hold
t
t