Descriptions of options
Note:
All options are not available for all drive types, do not coexist with certain other
options, or may require additional engineering. Check actual availability with ABB.
■
Degree of protection
Definitions
According to IEC/EN 60529, the degree of protection is indicated by an IP code where
the first numeral means protection against ingress of solid foreign objects, and the
second numeral protection against ingress of water. The IP codes of the standard cabinet
and options covered in this manual are defined below.
The equipment is protected …
IP code
Second numeral
First numeral
against dripping (vertically falling drops)
against ingress of solid foreign objects >
12.5 mm diameter*
IP21
against dripping (15° tilting) water
against ingress of solid foreign objects >
1 mm
IP42
against splashing water
dust-protected
IP54
* meaning for protection of persons: against access to hazardous parts with finger
IP21 (UL Type 1)
The degree of protection of the standard drive cabinet is IP21 (UL type 1). The air outlets
at the top of the cabinet and the air inlet gratings are covered with metallic gratings.
With doors open, the degree of protection of the standard cabinet and all cabinet options
is IP20. The live parts inside the cabinet are protected against contact with clear plastic
shrouds or metallic gratings.
IP42 (UL Type 1 Filtered) (B054)
This option provides the degree of protection of IP42 (UL type 1). The air inlet gratings
are covered with a metallic mesh between the inner and outer metallic gratings.
IP54 (UL Type 12) (B055)
This option provides the degree of protection of IP54 (UL type 12). It provides the cabinet
air inlets with filter housings containing folded board air filter mats between the inner
and outer metallic gratings. An additional fan and filtered outlets on the cabinet roof are
also included.
■
UL Listed (C129)
The cabinet contains the following accessories and features:
54 Operation principle and hardware description
Summary of Contents for ACQ580-07
Page 1: ... ABB DRIVES FOR WATER ACQ580 07 Hardware manual ...
Page 2: ......
Page 4: ......
Page 8: ...4 Update notice ...
Page 20: ...16 ...
Page 26: ...Measuring points of frames R6 to R9 are shown below PE L1 L2 L3 22 Safety instructions ...
Page 32: ...28 ...
Page 38: ...34 ...
Page 66: ...62 ...
Page 69: ...Mechanical installation 65 ...
Page 73: ... Mechanical installation 69 ...
Page 75: ...Declaration of Conformity Mechanical installation 71 ...
Page 108: ...104 ...
Page 133: ...Electrical installation 129 ...
Page 142: ...138 ...
Page 156: ...152 ...
Page 162: ...158 ...
Page 171: ...Maintenance 167 ...
Page 177: ...3 4 Maintenance 173 ...
Page 184: ...14 13 15 16 17 Remove the flange 180 Maintenance ...
Page 187: ...3 4 5 6 Remove the mounting plate Maintenance 183 ...
Page 189: ...8 Disconnect the drive module output busbars M12 70 N m 52 lbf ft 7 8 Maintenance 185 ...
Page 193: ...4 5 3 6 Remove the mounting plate Maintenance 189 ...
Page 195: ...8 Disconnect the drive module output busbars M12 70 N m 52 lbf ft 7 8 Maintenance 191 ...
Page 218: ...Frame R6 Input and motor cable terminal dimensions option F289 DET A 214 Technical data ...
Page 233: ...Frame R9 Input and motor cable terminal dimensions option F289 Technical data 229 ...
Page 257: ...13 Dimension drawings Example dimension drawings are shown below Dimension drawings 253 ...
Page 258: ...Frames R6 and R7 IP21 UL Type 1 254 Dimension drawings ...
Page 259: ...Frames R6 and R7 B054 IP42 UL Type 1 Filtered Dimension drawings 255 ...
Page 260: ...Frames R6 and R7 B055 IP54 UL Type 12 256 Dimension drawings ...
Page 261: ...Frames R6 and R7 H351 and H353 top entry and exit Dimension drawings 257 ...
Page 262: ...Frames R6 and R7 F289 258 Dimension drawings ...
Page 263: ...Frames R6 and R7 F289 H351 H353 Dimension drawings 259 ...
Page 264: ...Frames R8 and R9 IP21 UL Type 1 260 Dimension drawings ...
Page 265: ...Frames R8 and R9 B054 IP42 UL Type 1 Filtered Dimension drawings 261 ...
Page 266: ...Frames R8 and R9 B055 IP54 UL Type 12 262 Dimension drawings ...
Page 267: ...Frames R8 and R9 H351 and H353 top entry and exit Dimension drawings 263 ...
Page 268: ...Frames R8 and R9 F289 264 Dimension drawings ...
Page 269: ...Frames R8 and R9 F289 H351 H353 Dimension drawings 265 ...
Page 295: ... Declaration of conformity The Safe torque off function 291 ...
Page 296: ...292 ...
Page 302: ...298 ...
Page 309: ...CMOD 01 multifunction extension module external 24 V AC DC and digital I O 305 ...
Page 310: ...306 ...
Page 316: ...312 CMOD 02 multifunction extension module external 24 V AC DC and isolated PTC interface ...
Page 322: ...318 ...