206 Parameters
06.05
TORQ LIM STATUS
Torque controller limitation status word
0x0000...0xFFFF Torque limit status.
1 = 1
08
08 ALARMS &
FAULTS
Signals containing alarm and fault information.
08.01
ACTIVE FAULT
Shows the fault code of the latest (active) fault.
0...65535
Fault code
1 = 1 / -
08.02
LAST FAULT
Shows the fault code of the 2nd latest fault.
0...2147483647
Fault code
1 = 1 / -
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Bit
Name
Value Information
0
UNDERVOLTAGE
1
Intermediate circuit DC undervoltage. *
1
OVERVOLTAGE
1
Intermediate circuit DC overvoltage. *
2
MINIMUM TORQUE 1
Torque reference minimum limit is active.*
3
MAXIMUM TORQUE 1
Torque reference maximum limit is active.*
4
INTERNAL
CURRENT
1
An inverter current limit is active. The limit is
identified by bits 8…11.
5
LOAD ANGLE
1
For permanent magnet motor only: Load angle
limit is active, ie, the motor cannot produce more
torque.
6
MOTOR PULLOUT
1
For asynchronous motor only: Motor pull-out limit
is active, ie, the motor cannot produce more
torque.
7
RESERVED
8
THERMAL
1
Bit 4 = 0: Input current is limited by main circuit
thermal limit. Bit 4 = 1: Output current is limited by
main circuit thermal limit.
9
I2MAX CURRENT
1
Inverter output current limit is active. **
10
USER CURRENT
1
Maximum inverter output current limit is active.
The limit is defined by parameter
MAXIMUM CURRENT. **
11
THERMAL IGBT
1
Calculated thermal current value that limits the
inverter output current.
12...15 RESERVED
* Only one of the bits 0…3 can be On simultaneously. The bit typically indicates the limit
that exceeds first.
** Only one of the bits 9…11 can be On simultaneously. The bit typically indicates the
limit that exceeds first.
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...