132 Program features
Basic start/stop operation
The basic start/stop functions can be used for the elevator start/stop control and the
interlocks related to basic operation.
Start/stop control
Start/stop control comprises the logic and commands for starting the elevator in
upward and downward directions. Starting method can be selected with parameter
START FUNC. There are two basic methods:
•
– this selection defines separate start signals for upward and
downward directions. The source selected with
UP COMMAND is the start
up (upward) signal and the source selected with
DOWN COMMAND is the
start down (downward) signal.
•
– this selection defines one signal for start and another signal for the
direction of the elevator. The source selected with
UP COMMAND is the
start signal and the source selected with
DOWN COMMAND is the direction
(0 = up, 1 = down).
Start/stop control operates in the normal travel mode, releveling mode and
evacuation mode. The inspection mode has a start/stop control of its own. For more
information, see section
on page
Settings
Start/stop interlocking
The start/stop interlocking function stops or blocks the start command using
parameter
LIFT RUN ENABLE without generating any fault or warning in the
drive. When the signal configured with parameter
is switched Off, the drive will
not start, or if the drive is running, it will stop.
Settings
Parameters
Additional information
START FUNC
Selects the source for the start and stop control in external control.
Selects the source 1 for the start and stop commands in external control.
DOWN COMMAND
Selects the source 2 for the start and stop commands in external control.
Parameters
Additional information
LIFT RUN ENABLE
Selects the source for the Run enable signal.
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...