216 Parameters
10.07
DC MAGN TIME
Defines the constant DC magnetising time. After the
start command, the drive automatically
premagnetises the motor at the set time.
To make sure that motor is magnetised fully, this
value can be set to the same value as or higher than
the rotor time constant. If value is not known, use the
rule-of-thumb value given in the table below:
Note:
This parameter cannot be changed while the
drive is running.
500 ms/
0…10000 ms
DC magnetising time.
1 = 1 ms
10.80
LIFT RUN ENABLE
Selects the source for the Run enable signal.
1 = Run enable
When the Run enable signals is switched Off, the
drive will not start, or if the drive is running, it will
stop.
Note
: This parameter cannot be changed while the
drive is running.
C.TRUE /
Bit pointer: CONST or POINTER (See
.)
10.81
EVACUATION
MODE
Selects the source for enabling/disabling the
evacuation mode.
1 = Evacuation mode is enabled.
0 = Evacuation mode is disabled.
The evacuation mode is used for a lift car rescue
operation in case the power supply fails. For more
information, see section
page
.
C.FALSE/
Bit pointer: CONST or POINTER (See
.)
10.82
EVACUATION
AUTO
Selects the manual or automatic evacuation mode.
DISABLED/
DISABLED
Manual evacuation mode is enabled.
0
AUTOMATIC
Automatic evacuation mode is enabled. In this mode
drive measures the direction of the lighter load and
selects the evacuation direction accordingly.
1
No.
Bit/Name/Value/
Range
Description
Def/Type
FbEq
(16b/32b)
Motor rated power
Constant magnetising
time
< 1 kW
> 50 to 100 ms
1 to 10 kW
> 100 to 200 ms
10 to 200 kW
> 200 to 1000 ms
200 to 1000 kW
> 1000 to 2000 ms
Summary of Contents for ACL30
Page 1: ...ABB high performance elevator drives User s manual ACL30 elevator drive ...
Page 4: ......
Page 20: ...20 Safety instructions ...
Page 34: ...34 Operation principle and hardware description ...
Page 42: ...42 Planning the cabinet installation ...
Page 60: ...60 Planning the electrical installation ...
Page 126: ...126 Using the control panel ...
Page 318: ...318 Maintenance ...
Page 334: ...334 The Safe torque off function ...
Page 338: ...338 Mains chokes ...
Page 342: ...342 EMC filters ...
Page 348: ...Dimension drawings 348 Frame size B D1 D2 W H1 H2 ...
Page 349: ...Dimension drawings 349 ...
Page 350: ...Dimension drawings 350 Frame size C D1 D2 H2 H1 W ...
Page 351: ...Dimension drawings 351 ...
Page 352: ...Dimension drawings 352 Frame size D ...
Page 354: ...354 Dimension drawings EMC filters JFI 0x ...
Page 356: ...356 Dimension drawings Brake resistors JBR xx ...
Page 358: ...358 Dimension drawings ...