Chapter 2 – Mechanical Installation
ACA 6xx Sections and ACS/ACC 6x7 (132 to 3000 kW) Frequency Converters
2-11
Vibration Dampers on
Top and Bottom (Marine
Versions)
The shipping split must be fastened to the floor and roof (wall) in
marine versions as follows.
Vibration damper flat bar
Use M10 or M12 screws.
(Do not weld!)
1. Fasten the shipping split to the floor with
M10 or M12 bolts through the holes in
the vibration damper flat bar.
2. If there is not enough room behind the
cabinets for installation, use the
fastening method shown in figure (2).
3. Fasten the upper vibration dampers.
For the positions of the upper
vibration dampers, see the
accompanying dimension drawing of
the shipping split!
4. Fasten the support arms to the upper
vibration dampers and roof (wall).
Use a clamp (not included)
Upper vibration dampers
Use M12 screws.
Support arm
(not included)
Side view
1
2
3
Selflocking nut
M12-DIN985.
Torque 13 Nm.
Top view