Operation Manual / 4 Product description / A100-L
4
Monitoring during operation
Page 25 / 113
© Copyright 2016 ABB. All rights reserved.
HZTL4034_EN
Revision H
November 2016
4.2.4
Replacing the speed sensor
WARNING
Hot cable connector and hot speed sensor
Danger of burns. The cable connector and the speed sensor can reach tem-
peratures of more than 100 °C during operation.
When disassembling the cable connector and speed sensor, wear safety
gloves.
Wear safety gloves to protect against thermal hazards.
NOTICE
Sealing of the speed sensor
The speed sensor is designed with a sealing lip and does not require a seal-
ing disc for assembly.
Figure 9: Replacing the speed sensor
Part number
A165-L
A170-L
A175-L
A180-L
A185-L
A190-L
86505
M18x1.5
150 Nm
M18x1.5
150 Nm
M18x1.5
150 Nm
M27x2
320 Nm
M27x2
320 Nm
M27x2
320 Nm
Table 9: Tightening torques (86505)
Reduce the engine performance to idling and then stop the engine. Pay attention to post-
lubrication (
Switch off the lubricating oil supply to the turbocharger.
Disconnect the cable connector from the speed sensor.
Unscrew defective speed sensor.
Screw in new speed sensor to the stop.
Connect cable connector (86515) with the speed sensor (86505)
Switch on lubricating oil supply to the turbocharger.