Operating Instructions
Busch-Welcome
®
Installation and electrical
connection
Operating Instructions | 1473-1-8354
— 37 —
Pos: 89 /#Neustruktur#/Leermodule/-----------------------------------------Montage und elektrischer Anschluss ------------------------ @ 25\mod_1340800921288_15.docx @ 220439 @ 2222222222122222222222222222222222222221222222222222222222222222222222222222222222222222222222222222222222222 @ 1
Pos: 90 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/1. Ebene/M - O/Montage und elektrischer Anschluss @ 23\mod_1336477157864_15.docx @ 209033 @ 22212222222222222222222222222222212222222222222222222222222222222222222222222222222222222222222222222222222222222222222222222 @ 1
11
Installation and electrical connection
Pos: 91 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Niederspannungs- und 230 V-Leitungen @ 23\mod_1336558868201_15.docx @ 209164 @ 222222222222222222222222222221222222222222222222222 @ 1
Warning
Electric voltage!
Risk of death due to electrical voltage of 230 V during short-circuit in the low-voltage line.
–
Low-voltage and 230 V lines must not be installed together in a flush-mounted socket!
Pos: 92 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - Fachkenntnisse @ 23\mod_1336559183027_15.docx @ 209179 @ 222222222222 @ 1
11.1
Requirements for the electrician
Warning
Electric voltage!
Install the device only if you have the necessary electrical engineering knowledge and experience.
•
Incorrect installation endangers your life and that of the user of the electrical system.
•
Incorrect installation can cause serious damage to property, e.g. due to fire.
The minimum necessary expert knowledge and requirements for the installation are as follows:
•
Apply the "five safety rules" (DIN VDE 0105, EN 50110):
1. Disconnect from power;
2. Secure against being re-connected;
3. Ensure there is no voltage;
4. Connect to earth and short-circuit;
5. Cover or barricade adjacent live parts.
•
Use suitable personal protective clothing.
•
Use only suitable tools and measuring devices.
•
Check the supply network type (TN system, IT system, TT system) to secure the following
power supply conditions (classic connection to ground, protective earthing, necessary
additional measures, etc.).
Pos: 93 /#Neustruktur#/Online-Dokumentation (+KNX)/Sicherheitshinweise und Hinweise (--> Für alle Dokumente <--)/Warnhinweise/Sicherheit - 230 V @ 18\mod_1302606816750_15.docx @ 103308 @ 11111112222222222222222222222222222222222222222222222222222222222222222222222222221 @ 1
Warning
Electric voltage!
Risk of death and fire due to electrical voltage of 230 V.
–
Work on the 230V supply system may only be performed by authorised electricians!
–
Disconnect the mains power supply prior to installation and/or disassembly!
Pos: 94 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 221111111222222222222222222222222222222222222222222222222222222222222222122222222222221111111111121111111111111111111111111111111111111111112222222 @ 1
11.2
Mounting
Pos: 95 /#Neustruktur#/Online-Dokumentation (+KNX)/Montage/alle Geräte/Montage - Hutschienen nach DIN EN 500022 - Ohne Docvariable @ 20\mod_1325766045140_15.docx @ 136603 @ 22222222222222211111111111211111111111111111111111111111111111111111122222221111111111111111111111111111111121 @ 1
The MDRC must only be installed on mounting rails according to DIN EN 500022. The MDRC is latched onto the
mounting rail.