ABB-Welcome
|
— 10 —
4.3
Programming mode
start
1. Long press “
Prog
” button for
3s
to
enter programming mode
2. Choose cameras to set by dip switch
V1/V2/V3/V4
4. Set the working mode by
R1
Mode=1, Camera interface works as an independent
outdoor station
.
Mode=2, Camera interface works associated with
outdoor station
.
Mode=3, Camera interface works associated with
guard unit
.
Mode=4, Camera interface works associated with
indoor station
3. Assign the address of the camera
interface by
R3
5. Short-press "
Prog
" button to save current setting
6. Set the address of the associated
device by these three rotary switches
(R1&R2&R3)
Address=R1*100+R2*10+R3
continue to
program
8. Long press “
Prog
” button
3s
to exit
programming mode
End
7. Short-press "
Prog
" button to save
current setting
N
Y
R1
R2
R3