Operating Instructions
Busch-AudioWorld
®
Installation and electrical
connection
Operating Instructions | 1473-1-8313
— 7 —
Pos: 25 /#Neustruktur#/Online-Dokumentation (+KNX)/Montage/alle Geräte/Montagehinweise - Allgemein @ 33\mod_1360846993155_15.docx @ 277666 @ 2 @ 1
5.2
General mounting instructions
•
Terminate all branches of the wiring system via a connected bus device (e.g., indoor station, outdoor station,
system device).
•
Do not install the system controller directly next to the bell transformer and other power supplies (to avoid
interference).
•
Do not install the lines of the system bus together with 230 V- lines.
•
Do not use common cables for the connecting wires of the door openers and wires of the system bus.
•
Avoid bridges between different cable types.
•
Use only two wires for the system bus in a four-core or multi-core cable.
•
When looping, never install the incoming and outgoing bus inside the same cable.
•
Never install the internal and external bus inside the same cable.
Pos: 26 /#Neustruktur#/Online-Dokumentation (+KNX)/Überschriften (--> Für alle Dokumente <--)/2. Ebene/M - O/Montage @ 18\mod_1302615960458_15.docx @ 103424 @ 2222 @ 1
5.3
Mounting
Pos: 27 /#Neustruktur#/Online-Dokumentation (+KNX)/Montage/alle Geräte/Montage - Hutschienen nach DIN EN 500022 - Ohne Docvariable @ 20\mod_1325766045140_15.docx @ 136603 @ @ 1
The MDRC must only be installed on mounting rails according to DIN EN 500022. The MDRC is latched onto the
mounting rail.