1.3.2 Operating requirements
Protection standard
Protection standard IEC529
Robot variant
IP40
All variants, manipulator
IP67
Option, all variants
Explosive environments
The robot must not be located or operated in an explosive environment.
Working range limitations
EPS will not be selectable. No mechanical limitation.
Ambient temperature
Temperature
Protection class
Description
+ 5°C
i
(41°F) to + 45°C (113°F)
Standard
Manipulator during opera-
tion
+ 5°C
(41°F) to + 35°C
ii
(113°F)
Option
Manipulator with food
grade lubrication during
operation
See
Product specification - Control-
ler IRC5
Standard/Option
For the controller
- 25°C (-13°F) to + 55°C (131°F)
Standard
Complete robot during
transportation and storage
up to + 70°C (158°F)
Standard
For short periods (not ex-
ceeding 24 hours)
i
At low environmental temperature < 10ºC is, as with any other machine, a warm-up phase
recommended to be run with the robot. Otherwise there is a risk that the robot stops or run with
lower performance due to temperature dependent oil and grease viscosity.
ii
For robots with food grade lubrication, if environment temperature > 35ºC, contact ABB for further
information.
Relative humidity
Relative humidity
Description
Max. 95% at constant temperature
Complete robot during operation, transportation and
storage
20
Product specification - IRB 1200
3HAC046982-001 Revision: G
© Copyright 2017 ABB. All rights reserved.
1 Description
1.3.2 Operating requirements
Summary of Contents for IRB 1200
Page 1: ...ROBOTICS Product specification IRB 1200 ...
Page 6: ...This page is intentionally left blank ...
Page 48: ...This page is intentionally left blank ...
Page 58: ...This page is intentionally left blank ...
Page 60: ......
Page 61: ......