IV. INSTRUCTION FOR USE:
1. Before operating:
- Ensure the equipment is connected to suitable voltage power (See
section II)
- Ensure the power is continuous supplied during the whole operate
process.
- Inspect the air tube system, ensure there is not sign of leaking or
breaking.
- Ensure the slab surface is clean, no sign of any liquid such as water
and oil.
- Ensure all the suction cups are carefully cleaned up.
- Inspect all the buttons, levers, alarm.
2. Operating Instruction:
A. When the glass is positioned in vertical dimension:
Step 1:
Moving the glass vacuum lifter close to the glass.
Note:
11
- Adjusting the suction cups position to adapt to the glass size (See
appendix 3.B)
- Ensure the lifter is set at the centre of the glass relatively.