PowerFlex® 700S Drive
13
Figure 8 Power Terminal Block Location
BR1 B
SHLD
SHLD
V/T2 W/T3
PE R/L1 S/L2 T/L3
AUX IN+ AUX OUT–
Optional
Communications
Module
75C Cu Wire
6 AWG [10MM
2
] Max.
12 IN. LBS.
1.4 N-M
} TORQUE
WIRE
STRIP
CONTROL
POWER
BR1
BR2
DC+
DC–
PE
U/T1
V/T2
W/T3
R/L1
S/L2
T/L3
Use 75C Wire Only
#10-#14 AWG
Torque to 7 in-lbs
!
DANGER
Optional
Communications
Module
L2
L1
T3
T2
T1
L3
INPUT
OUTPUT
USE 75 C
COPPER WIRE
ONLY
TORQUE
52 IN-LB
(6 N-M)
BR2
PS+
PS–
BR1
DC+
DC–
USE 75 C COPPER WIRE ONLY, TORQUE 52 IN-LB (6 N-M)
22-10
AWG
5.3 IN-LB
(0.6 N-M)
WIRE STRIP
Frame 1
Frame 2
➊
➋
➊
➋
BR1 BR2 DC+ DC- U/T1 V/T2 W/T3 R/L1 S/L2 T/L3
Optional
Communications
Module
PE B
PE A
75C Cu Wire
3 AWG [25MM
2
] Max.
16 IN. LBS.
1.8 N-M
} TORQUE
WIRE
STRIP
CONTROL
POWER
AUX IN
+ –
SHLD
SHLD
PE
75C Cu Wire
6 AWG [10MM2] Max.
BR1 BR2
12 IN. LBS.
1.4 N-M
} TORQUE
WIRE RANGE: 14-1/0 AWG (2.5-35 MM
2
)
TORQUE: 32 IN-LB (3.6 N-M)
STRIP LENGTH: 0.67 IN (17 MM)
USE 75 C CU WIRE ONLY
POWER TERMINAL RATINGS
WIRE RANGE: 6-1/0 AWG (16-35 MM
2
)
TORQUE: 44 IN-LB (5 N-M)
STRIP LENGTH: 0.83 IN (21 MM)
GROUND TERMINAL RATINGS (PE)
300 VDC EXT PWR SPLY TERM (PS+, PS-)
WIRE RANGE: 22-10 AWG (0.5-4 MM
2
)
TORQUE: 5.3 IN-LB (0.6 N-M)
STRIP LENGTH: 0.35 IN (9 MM)
17
21
INPUT AC
OUTPUT
Optional
Communications
Module
9
480 Volt Tap
600 Volt Tap
690 Volt Tap
400 Volt Tap
Three-Phase
Single-Phase
Spare
Spare
Line Type
(default)
➌
➌
Frames 3 & 4
Frame 5
➊
➋
➌
➌
➋
Fan Voltage
1
1
Frame 5 & 6 utilize a transformer to match the input line voltage to the internal fan voltage.
If you line voltage is different then the voltage class specified on the drive nameplate, it
may be necessary to change the transformer taps. The taps are shown in the inserts of
frames 5 & 6.
Common Bus drives require user supplied 120V or 240V to power the cooling fans.
Power source is connected between “0V AC” and the terminal corresponding to your
source voltage (see common bus terminal blocks, page 15).
Phase Selection
Jumper
PE
/
➊
➋
➌
➊
Frame 6
➍
Fan VA Rating - Common Bus Only
Frame Fan Voltage
(120V or 240V)
5
100 VA
6
138 VA
➍