FREQUENTLY ASKED QUESTIONS
Electrical troubleshooting chart
1.
If the lights do not turn on.
•
Check the battery connection.
•
Make sure the battery switch is placed to the ON position.
•
Check the connections in the NAV/ANC Switch.
•
Make sure the lights are in good condition.
•
Check that fuses are not burned.
2.
The Bilge pump does not work in automatic position.
•
The floating sensor allows the bilge pump to work in the
automatic mode. Sometimes, sediment or debris can
accumulate, blocking the float switch or the impeller.
Remove the pump housing from the mounting base and
clean the float switch and impeller so that it can move freely.
3.
No device turns on even when the battery switch is in the
ON position.
•
This may be because the main fuse has burned. Check the
fuses in the fuse holder. If necessary, proceed to replace the
fuses with the same capacity as indicated.
•
Always keep your maintenance kit and spare fuses at hand.
•
Remember to turn OFF your battery switch whenever the
boat will not be used for long periods of time. This will prevent a
battery load loss if an electrical device is left on accidentally.
CAUTION
Never:
•
Work on the electrical installation while the system is energized.
•
Modify the craft's electrical system. Installation, alterations and
maintenance should be performed by a competent marine electrical
technician.
•
Alter or modify the rated current amperage of over current protective
devices.
•
Install or replace electrical appliances or devices with components
exceeding the rated current amperage of the circuit.
•
Leave the craft unattended with the electrical system energized,
except automatic bilge-pump, fire protection and alarm circuits.
38
Summary of Contents for ABJET 285
Page 1: ...Owner s manual ...