background image

Copyright © 2015 AAS Technology 

 

AH-5

 

www.AAS.com.tw 

R201507-V27 

Specification       

 

 

 

 

 

                                     

 

      

  .. 

 

Model   

VPH-400 

Transmission & Video 

Properties 

Transmission Channel 

4 Channels 

Video Connector 

4 Channels 

Transmission Distance 

Refer to ‘Table 1’ below 

Compatible Video Format 

HD TVI, HD CVI, AHD, CVBS 

Video Transmission 

Performance and Connection 

Properties 

Coaxial Video Connector 

Female BNC Connector 

UTP Cable Connector 

Female RJ45 Connector 

8 Pin Screw Push Terminal 

Signal Transmission Width 

0~70MHz 

Anti-interference 

>60dB 

Protection Level 

Coaxial Video Connector Surge 

2KV per

IEC61000-4-5 

UTP Cable Communicatin 

Connector Surge Protection 

2KV (different mode) per:IEC61000-4-5 

ESD 

1a contact discharge level 3 

1b air discharge level 3 

per : IEC61000-4-2 

Operation Environment 

Operation Temperature 

0°C~55°C / 32°F~131°F 

Storage Temperature 

-40°C~85°C / -40°F~185°F 

Humidity 

0~95% 

Physical Properties 

Dimension (L x W x H) 

85 x 82 x 25 mm / 3.35 x 3.22 x 0.98 inches 

(connector length included) 

Housing Material 

Aluminum 

Color 

Black 

Net Weight 

154g / 5.4 oz 

*Specifications are subject to change without notice 

 

Table-1**: 

Single Source 

HD TVI 

(720P/1080P) 

HD CVI 

(720P) 

HD CVI 

(1080P) 

AHD-L/M 

(720P/960P) 

AHD-H 

(1080P) 

Analog Video 

Recommended 

Distance 

200m / 650ft 

370m / 1200ft 

100m / 300ft 

330m / 1050ft 

330m / 1050ft 

500m / 1600ft 

**The test data in Table 1 is required under lab environment by passive to passive. In actual case, there may be some differences due to different cable and environment. 

 

 

 

Troubleshooting          

 

 

 

 

                                     

 

      

  .. 

 

If the equipment fails, follow the methods below to troubleshoot. 

 

Make sure equipment installation is according to the manual. 

 

If RJ45 is chosen, make sure both ends of UTP cable are the same (both 568A or both 568B). 

 

If green terminal block is chosen, make sure the same colored cable are in the same pin. 

 

Maximum transmission distance depends on the quality of the signal source and the transmission cable. Do not exceed the equipment maximum 

transmission distance. 

 

Check whether connection is correct. Charge the device when there is no image. 

 

Replace 

VPH400

 to see if failed device is defective. 

 

 

 

 

 

 

 

 

Pin

 

Pair

   

Color

 

1

 

2

 

Orange 

/ White

 

2

 

2

 

Orange

 

3

 

3

 

Green 

/ White

 

4

 

1

 

Blue

   

5

 

1

 

Blue 

/ White

 

6

 

3

 

Green

 

7

 

4

 

Brown 

/ White

 

8

 

4

 

Brown

 

1    2    3    4    5    6   

   

 

Pair 3

 

Pair 1

 

Pair 2

 

Pair 4

 

TIA/EIA 568B

 