background image

ANNUAL MAINTENANCE

It is important that your fire is regularly serviced in
accordance with these instructions.  This should be
carried out at least annually by a qualified person
and should consist of the following.

Remove the firebricks lining and throat plate,
inspect all gasketing on doors, glass etc., and
re-order any items that may need replacing, from
your Aarrow dealer. With a wire brush clean inside
the appliance paying particular attention to the
small inlet holes of the air wash on the inside,
above the fire door and to the door. 

Sweep the chimney and confirm that it is sound.
Examine all joints in the flue pipe etc., and re-seal
if necessary. Reassemble and leave with the air
inlet and air wash control about half way open. This
will allow a free flow of air through the appliance
thus preventing moisture and condensation from
building up inside the fire and chimney.

CHIMNEY SWEEPING

Sweeping should be carried out with an appropriate
sized bristle brush and rods to suit chimney size and
type. As with all appliances regular sweeping of the flue
is essential to avoid the danger of blockage and the
escape of  poisonous fumes. Access for cleaning should
also be incorporated in the chimney (e.g. soot door or
access through register plate).

Any existing chimney should be swept prior to
installation of the appliance, and swept again a
second time 

within one month 

of regular use after

installation to establish frequency of sweeping
required. This should be done by a competent
person such as a NACS chimney engineer who will
provide a Certificate of Chimney Sweeping.

Sweep the whole flue way, including the outlet, at
least twice per burning season. It is important that
the flue ways, flue pipe and chimney be cleaned
prior to lighting the fire after a prolonged
shut-down period.

DOOR GLASS

The door glass should remain clear during normal
daytime burning. However under certain conditions-such
as burning at a low rate with damp wood, or overnight

burning, the glass may become somewhat blackened. To
remedy this, operate the appliance at a fast rate.
Alternatively when the stove is cold open the door and
clean the inside face of the glass with a damp cloth or
with glass cleaner  (available from fire stockists). Apiece
of cloth moistened with vinegar and dipped in wood ash

not coal ash

- will provide a good soft scourer to

remove the soot without scratching the glass.

OUTER FINISH

The outside finish of the appliance is a durable high
temperature paint. It is best cleaned by brushing
down with a clean shoe brush. Do not allow
moisture to remain on the appliance whilst cold or
surface rust may form.

The high temperature paint should not require
attention for some time, depending on use. The
hotter the fire burns the sooner repainting will be
necessary. Aerosol tins of paint are available for
complete refurbishing. Before repainting make sure
that the fire is out and is cold.
•Remove the door glass.
•Lightly wire brush, or rub with wire wool, the 

body of the appliance to remove any loose paint  
powder.

•Mask or remove items such as brass work.
•Any adjacent brickwork, mantelpiece, hearth, 

etc., should be carefully masked for quite a 
distance around the appliance. (this precaution is 

to prevent discolouration of the surrounding brick

work, wallpaper etc).

Re-spray in a well-ventilated area - avoid breathing
the vapour. Refer to safety instructions on paint
cans. 

•When the paint is dry refit door glass and any 

other parts previously removed.

•Leave the appliance for eight hours before

re-lighting. 

•Burn slowly for the first four hours, then build up 

heat gradually to cure the paint.

Note: Use only genuine Aarrow touch-up spray as
some paints interact. This could ruin the finish
and invalidate the guarantee.

14

Beacon Multifuel Stoves

SERVICING

Summary of Contents for Beacon

Page 1: ...Beacon Multifuel Stoves Operating Installation Manual PLEASE RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE Rev 1 October 2005 AFS 1269 AARROW BEACON 75 SHOWN...

Page 2: ...which is why we are so confident in the reliability of our product Should you have any questions about our Beacon Stoves that are not covered in this manual please contact the Aarrow dealer in your a...

Page 3: ...Types 11 Lighting The Fire 11 12 Overnight Burning 12 Over Firing 13 Cleaning 13 Annual Maintenance 14 Accessories 15 INSTALLATION Page General Precautions 16 Handling 16 Hearth 16 Combustible Materi...

Page 4: ...BE BURNED IN THIS APPLIANCE TO USE THESE FUELS WILL INVALIDATE THE APPLIANCE GUARANTEE IF IN DOUBT CONTACT THE SOLID FUEL ASSOCIATION TELEPHONE NUMBER 0800 600 000 www solidfuel co uk THE USE OF SPAR...

Page 5: ...properly installed and operated a house fire may result installation must comply with the Building Regulations and conform to all relevant fire safety standards Arada Ltd produce a variety of applian...

Page 6: ...n Multifuel Stoves CHECK LIST Part Description Visual Aid not to scale Beacon 75 Beacon 77 2 Throat plate 1 1 3 Flue spigot 1 5 1 5 4 Hot plate 1 5 1 5 5 Ash pan 1 1 6 Operating tool 1 1 7 Rear liner...

Page 7: ...75 Beacon 77 Room Heater with Domestic Hot Water with add in boiler type N A N A Max Output to Room kW Max Output to Water kW N A N A Height mm 548 543 Width mm 476 482 Depth mm 345 345 Height to Cent...

Page 8: ...ating the door knob if hot with a suitable glove anti clockwise to increase the the air inlet clockwise to reduce the air inlet or seal the ash door completely Note Opening or part opening of the ash...

Page 9: ...DOOR TRIM Beacon fire doors are fitted with a brushed steel finish trim as standard This clips on to the small lugs at the top and bottom of the aperture in the cast iron fire door as a spring fit Wh...

Page 10: ...oor so that it is at a right angle to the front face of the fire Lift the fire door up off the hinges Gently tap the two hinge pins in a direction to compensate for the misalignment fig 7 Refit the do...

Page 11: ...nacite Plus Centurion Maxibrite Extracite Pureheat Blazebrite Taybrite Sunbrite Doubles Singles Anthracite Large Nuts and Welsh Dry Steam Coal Large Small Nuts Approval does not cover the use of other...

Page 12: ...ventilated during this time OVERNIGHT BURNING The appliance will burn overnight provided Sufficient fuel is placed in the firebox The controls are set correctly Excess draught is not present in the c...

Page 13: ...y clinker forming on the grate should be removed when cold OVER FIRING Do not over fire your appliance Using flammable liquids or too much wood or firing the fire at maximum for prolonged periods may...

Page 14: ...ged shut down period DOOR GLASS The door glass should remain clear during normal daytimeburning Howeverundercertainconditions such as burning at a low rate with damp wood or overnight burning the glas...

Page 15: ...n multifuel stove PAINT Matching aerosol paint to tone in any connecting flues pipes or surrounding metalwork INTERCHANGEABLE CANOPIES To fit the interchangeable canopy Fig 8 Remove the front clamps T...

Page 16: ...EARTH The fire should be installed to stand on a constructional hearth of non combustible materials not less than 125mm 5 thick conforming to Building Regulations Dimensions of the hearth should proje...

Page 17: ...on the side landings behind the top edge of the grate Fig 11 Fit the throat plate with the single bend and two cut outs to the front facing up The projecting lugs sit on top of the side liners The lo...

Page 18: ...t it is important that the flue gases are kept warm and that the flue size suits the stove The termination of the outlet at the top of the flue also needs to comply with the Building Regulations The m...

Page 19: ...rth and fireplace installation Approved Document J of the Building Regulations for England and Wales is available from The Stationery Bookshops and can also be viewed at the ODPM website at www safety...

Page 20: ...20 Beacon Multifuel Stoves INSTALLATION...

Page 21: ...THE CHIMNEY MANUFACTURERS INSTRUCTIONS IN COMPLIANCE WITH BUILDING REGULATIONS AND BS7566 PTS 1 4 PLAN VIEW OF REGISTER PLATE AND CLEARANCES FOR NON INSULATED FLUES A is minimum clearance for non insu...

Page 22: ...pliances only c If clay or concrete flue liners used confirm that they are correctly jointed with socket end uppermost and state jointing materials used d If an existing chimney has been refurbished w...

Page 23: ...Manual AFS1269 AFS1269 AFS1019 AFS1019 AFS1083 AFS1083 AFS010 AFS010 AFS008 AFS008 AFS058 AFS058 AFS009 AFS009 2 Throat Plate 3 Grate 4 Hot Plate 5 Operating Tool 6 Ashpan 7 Flue Spigot Part Descripti...

Page 24: ...9 AFS088 AFS070 AFS089 AFS047 AFS047 AFS1077 AFS1077 9 Side Liner 10 Back Liner Set 11 Glass Replacement Kit Complete with Gasket 12 Glass Clips and Gasket 13 Hinge kit Comprises 2 Hinges 4 Fixings Pe...

Page 25: ...AFS1270 AFS1272 AFS094A AFS095 AFS1146 AFS1146 AFS997 AFS997 16 Main Door Assembly Complete with Handle Glass Gaskets Clips and Seal 17 Decorative Door Surround 18 Fire Door Locking Assembly 19 Aarro...

Page 26: ...ppliance being serviced and checked annually by a quali fied heating engineer The Manufacturers decision shall be final If your appliance proves to be defective as a result of faulty materials or work...

Page 27: ...Multifuel Stove that is not covered in this manual please contact your Aarrow retailer Please keep all repair receipts safely Please ensure you have this manual available when an engineer visits as th...

Page 28: ...OPERATING TOOL Model Serial No I ve checked it and it s O K Assembled by Checked by Date of Purchase Name and address of supplier Please ensure installer completes INSTALLATION CHECK LIST details on...

Reviews: