Aaronn 100014153 Quick Start Manual Download Page 2

 

   

 

 

Quick reference Guide / Safety instructions 

 

Technical Details:   

 

Power input:  

90 – 264 V AC  (47-63Hz) 

 

Power output: 12VDC max. 5A (60 Watt) 

 

Operating temperature: 0-40 degree Celsius 

 

Humidity: 10% - 90% (

noncondensing

 

Dimension: 252mm x 241 mm x 37 mm 

 

NOTES: 

 

*

 Only available if supported by the OPS Module. 

 

*

 No Display port to DVI/HDMI adapters supported

 

*For RS232, only the GND,TX and RX pins are available

 

 

 

 

 

 

Step 1

: Plug the STv2/OPS Option in to the Adapter. 

Step 2

: Fix the STv2/OPS Option with the two screws 

Step 3

If you want to use the system as a desktop unit, install 

the supplied feet on the bottom. To fix the system to a display, 
display mount or a wall, use the eyelets on the side.

 

Step 4

Plug the cables and finally the power cord. Turn on the unit 

with the on / off switch.

 

 

The System has been built and tested by Aaronn Electronic GmbH in accordance to IEC/EN/UL/CSA 60950 and left the company in a perfectly safe condition. In order to maintain this condition and ensure safe operation, the user must observe the instructions and warnings contained in 
this manual. The device must be used in accordance with the instructions for use. 

 

Repairs may only be carried out by qualified specialist personnel authorized by Aaronn Electronic GmbH. 

 

The electrical installations in the room must correspond to the requirements of the local (country-specific) regulations. 

 

The device generates heat during operation. Do not cover the air intake and exhaust openings of the device. This ensures  proper ventilation. Do not 

use the system in areas (e.g. housing) where no or inadequate air circulation exists. Provide unobstructed ventilation by 

maintaining at least 10cm distance from 

air intake and exhaust openings 

to its environment.

 

 

Do not expose the device to direct sunlight or place it near heat sources or in damp places. Make sure the device has adequate ventilation. 

 

Only devices and components which fulfill the requirements of an SELV circuit (safety extra low voltage) in accordance with EN60950 may be connected to the interfaces of the system. 

 

Before plugging in a STv2/OPS module it has to be ensured that the power cord is disconnected. Switching off the device by power button, does not disconnect it from the mains. 
Complete disconnection is only possible if the power cable is removed from the wall plug or from the device. Ensure that there is free and easy access to enable disconnection. 

 

Do not open the STv2 Adapter. There are no User-serviceable parts inside. 

 

Aaronn Electronic GmbH, Zeppelinstrasse 2, 82178 Puchheim, Germany. All rights reserved. All specifications are subject to change without notice.  